Report No.: 17032770 001 
 
 
 
 
 
 
IEC 60065 
Clause 
Requirement + Test 
 Result - Remark 
Verdict 
 
TRF No. IEC60065K 
10.1 
Insulation resistance (MΩ) at least 2 MΩ min. after 
surge test for basic and 4 
MΩ min. for reinforced 
insulation  ............................................................: 
No antenna connection. 
N/A 
10.2 
Humidity treatment 48 h or 120 h  .........................: 
95% R. H., 40
o
C, 120h  
(manufacturer requirement) 
10.3 
Insulation resistance and dielectric strength between 
mains terminals  
(see appended table) 
 
Insulation Resistance and dielectric strength across 
BASIC or SUPPLEMENTARY insulation (Class I)  
 
N/A 
 
Insulation resistance and dielectric strength across 
REINFORCED insulation (Class II)  
 
 
11 
Fault conditions 
11.1 
No shock hazard under fault condition  
(see appended table 11.1) 
11.2 
Heating under fault condition  
 
 
Flames extinguish within 10 seconds  
No flames 
N/A 
 
No hazard from softening solder  
No softening solder 
N/A 
 
Soldered terminations not used  as protective 
mechanism  
 
11.2.1 
Measurement of temperature rises  
(see appended table) 
11.2.2 
Temperature rise of accessible parts  
(see appended table) 
11.2.3 
Temperature rise of parts, other than windings and 
printed boards, providing electrical insulation 
(see appended table) 
11.2.4 
Temperature rise of parts acting as a support or  
mechanical barrier  
 
11.2.5 
Temperature rise of windings  
(see appended table) 
11.2.6 
Temperature rise of printed boards shall not exceed 
the limits of table 3 by max. 100 K for max. 5 min 
(see appended table) 
 
Printed circuit boards (PCB) classified as V-0 
according to 60695-11-10 or Clause G.1 may 
exceed the limit in table 3 in case a) and b): 
 
N/A 
 
a) Temperature rise of printed circuit boards 
exceeding the limits of table 3 by not more than 
100 K for an area not greater than 2 cm²  ............... : 
 
N/A 
 
b) Temperature rise of printed circuit boards 
exceeding the limits of table 3 up to 300 K for an 
area not greater than 2 cm² for a maximum of 5 min  
 
N/A 
 
Meets all the special conditions if conductors on 
printed circuit boards are interrupted  
 
N/A 
 
Class I protective earthing maintained  
 
N/A 
Page of 108