Report No.: 17032770 001
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K
5.4.1
a) Mains powered equipment not exposed to
dripping or splashing. Warning concerning objects
filled with liquid, etc.
dripping or splashing. Warning concerning objects
filled with liquid, etc.
Stated in the instruction
P
b) Hazardous live terminals, instructions for wiring
No such terminals.
N/A
c) Instructions for replacing lithium battery
No battery used.
N/A
d) Class I earth connection warning
Class II apparatus
N/A
e) Instructions for multimedia system connection
P
f) Special stability warning for attachment of the
apparatus to the floor/wall
apparatus to the floor/wall
No such installation.
N/A
g) Warning: battery exposure to heat
No battery used.
N/A
h) Warning: protective film on CRT face
No CRT used.
N/A
5.4.2
a-b) Disconnect device: plug/coupler or all-pole
mains switch location, accessibility and markings
mains switch location, accessibility and markings
Stated in the instruction
regarding the power plug shall
be readily operable.
regarding the power plug shall
be readily operable.
P
c) Instructions for permanently connected equipment Not permanently connected
equipment.
N/A
Marking, signal lamps or similar for completely
disconnection from the mains
disconnection from the mains
N/A
6
Hazardous radiation
N/A
6.1
Ionizing radiation < 36 pA/kg (0,5 mR/h)
No such device
N/A
Ionizing radiation under fault condition
N/A
6.2
Laser radiation, emission limits to IEC 60825-1:2007
............................................................................:
............................................................................:
No laser produced.
N/A
Emission limits under fault conditions ....................:
N/A
7
Heating under normal operating conditions
P
7.1
Temperature rises not exceeding specified values;
fuse links and other protective devices defeated
fuse links and other protective devices defeated
(see appended table 7.1)
P
7.1.1
Temperature rise of accessible parts
(see appended table 7.1)
P
7.1.2
Temperature rise of parts providing electrical
insulation
insulation
(see appended table 7.1)
P
7.1.3
Temperature rise of parts acting as a support or as a
mechanical barrier
mechanical barrier
(see appended table 7.1)
P
7.1.4
Temperature rise of windings
(see appended table 7.1)
P
7.1.5
Parts not subject to a limit under 7.1.1 to 7.1.4
(see appended table 7.1)
P
7.2
Softening temperature of insulating material
supporting parts conductively connected to the
mains carrying a current > 0,2 A at least 150
supporting parts conductively connected to the
mains carrying a current > 0,2 A at least 150
o
C
(see appended table 7.2)
P