Report Ref No.: 614376
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No.: IEC60065E
TRF Originator: ASTABEAB
Terminals designed to avoid conductor slipping
out when tightened or loosened
out when tightened or loosened
N/A
Terminals adequately fixed to avoid loosening
when the clamping is tightened or loosened and
stress on internal wiring is avoided
when the clamping is tightened or loosened and
stress on internal wiring is avoided
N/A
15.3.8
Terminals carrying a current more than 0,2 A:
contact pressure not transmitted by insulating
material except ceramic
contact pressure not transmitted by insulating
material except ceramic
N/A
15.3.9
Termination of non-detachable cords: wires
terminated near to each other
terminated near to each other
N/A
Terminals located and shielded: test with 8 mm
strand
strand
N/A
15.4
Devices forming a part of the mains plug
15.4.1
No undue strain on mains socket-outlets
N/A
15.4.2
Device complies with standard for dimensions
of mains plugs
of mains plugs
N/A
15.4.3
Device has adequate mechanical strength
(tests a,b,c)
(tests a,b,c)
N/A
16 EXTERNAL
FLEXIBLE
CORDS
16.1
Mains cords sheathed type, complying with
IEC 60227 for PVC or IEC 60245 for synthetic
rubber cords ...................................................... :
IEC 60227 for PVC or IEC 60245 for synthetic
rubber cords ...................................................... :
PVC P
Non-detachable cords for Class I have
green/yellow core for protective earth
green/yellow core for protective earth
N/A
16.2
Mains cords conductors have adequate cross-
sectional area for rated current consumption of
the equipment
sectional area for rated current consumption of
the equipment
2x0.75mm
2
P
16.3
a) Flexible cords not complying with 16.1, used
for interconnections between separate units of
equipment used in combination and carrying
hazardous live voltages, have adequate
dielectric strength
for interconnections between separate units of
equipment used in combination and carrying
hazardous live voltages, have adequate
dielectric strength
N/A
b) Flexible cords not complying with 16.1,
withstand bending and mechanical stress (3.2
of IEC 60227-2)
withstand bending and mechanical stress (3.2
of IEC 60227-2)
N/A
16.4
Flexible cords used for connection between
equipment have adequate cross-sectional
areas to avoid temperature rise under normal
and fault conditions
equipment have adequate cross-sectional
areas to avoid temperature rise under normal
and fault conditions
N/A
16.5
Adequate strain relief on external flexible cords
N/A
Not possible to push cord back into equipment
N/A