TU 970II (serv.man4) - Harman Kardon Audio EMC - CB Certificate (repair manual). Page 12

Read Harman Kardon TU 970II (serv.man4) EMC - CB Certificate online

Page 10 of 24 
Report Reference No.: CPSA0106916 
 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
Test Report EN 60065E Rev. 00 / 2004-09 
 
 
a) Resistors between hazardous live parts and 
accessible metal parts 
No such resistors 
 
b) Resistors, other than between hazardous live 
parts and accessible parts 
 N 
 
b) Resistors separately approved ........................... : No 
14.2 
Capacitors and RC units 
 
 
Capacitors separately approved 
Yes 
14.2.1 
Y capacitors tested to IEC 60384-14, 2
nd
 edition  ... : Not used Y-capacitors 
14.2.2 
X capacitors tested to IEC 60384-14, 2
nd
 edition ... : C900 
(see appended table 14) 
14.2.3 
Capacitors operating at mains frequency but not 
connected to the mains: tests for X2 ...................... :
No N 
14.2.5 
Capacitors with volume exceeding 1750 mm³, 
where short-circuit current exceeds 0,2 A: 
compliance with IEC60384-1, 4.38 category B or 
better ....................................................................... :
 N 
 
Capacitors with volume exceeding 1750 mm³, 
mounted closer to a potential ignition source than 
table 5 permits: compliance with IEC 60 384-1, 
4.38 category B or better  ........................................ :
 N 
 
Shielded by a barrier to V-0 or metal ...................... : Metal chassis 
14.3 
Inductors and windings 
 
⎯ 
 
Comply with IEC 61558-1, IEC 61558-2 
(as relevant) and clause 20.1.4 
 N 
14.3.1 
Transformers and inductors marked with 
manufacturer's name and type ............................... :
Manufacturer’s Identification:  
SET 
Type: CLT5M026YE/ 
           KLT5M026YE 
 
Transformers and inductors separately approved . : No. Tested in apparatus 
14.3.2 General 
Isolation 
transformer 
14.3.3 Constructional 
requirements 
 
⎯ 
14.3.3.1 
Clearances and creepage distances comply with 
clause 13 
Complied with the 
requirements of clause 13 
14.3.3.2 
Transformers meet the constructional 
requirements 
Complied P 
14.3.4.1 
Class II transformers have adequate separation 
between hazardous live parts and accessible parts 
(double or reinforced insulation) 
Reinforced insulation  
 
Coil formers and partition walls > 0,4 mm 
 
14.3.4.2 
Class I transformers, with basic insulation and 
protective screening only if all 7 conditions of 
14.3.4.2 are met 
No such transformer used 
Windings of class II 
construction 
Page of 32