Report Reference No.: CPSA0106916 
 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
Test Report EN 60065E Rev. 00 / 2004-09 
 
14.5.2.4 
Not possible to touch hazardous live parts when 
replacing fuse-links without the use of a tool  ......... :
No replacement of fuse 
possible by hand 
14.5.3 
PTC-S thermistors comply with IEC 60730-1 
 
 
PTC-S devices (15 W) category V-1 or better 
 
14.5.4 
Circuit protectors have adequate breaking capacity 
and their position is correctly marked 
 N 
14.6 Switches 
 
⎯ 
14.6.1 a) 
Separate testing to IEC 61058 including: 
10 000 operations 
Normal pollution suitability 
Resistance to heat and fire level 3 
and 
V-0 compliance with annex G, G.1.1 
 P 
14.6.1 b) 
Tested in the apparatus: 
 
 
Switch controlling > 0.2A with open contact  voltage 
> 35 V (peak)/24 V dc complying with 14.6.3, 
14.6.4 and V-0 in annex G, G.1.1 
 N 
 
Switch controlling > 0.2A with open contact  voltage 
< 35 V (peak)/24 V dc complying with 14.6.3 and V-
0 in annex G, G.1.1 
 N 
 
Switch controlling < 0.2A with open contact  voltage 
> 35 V (peak)/24 V dc complying with  14.6.4 and 
V-0 in annex G, G.1.1 
 N 
14.6.2 
Switch tested to 14.6.1 b) constructed to IEC 
61058-1 subclause 13.1 and has making/breaking  
action independent of speed of actuation 
 N 
14.6.3 
Switch tested to 14.6.1 b) compliant with IEC 
61058-1 subclause 16.2.2 d) and  m) not attaining 
excessive temperatures in use 
 N 
14.6.4 
Switch tested to 14.6.1 b) has adequate dielectric 
strength 
 N 
14.6.5 
Mains switch controlling mains socket outlets 
additional tests to IEC 60058-1 
 N 
 
Socket outlet current marking correct 
 
14.7 
Safety interlocks 
No safety interlocks 
 
Safety interlocks to 2.8 of IEC 60950 
 
14.8 
Voltage setting devices 
No voltage setting devices 
 
Voltage setting device not likely to be changed 
accidentally 
 N 
14.9 Motors 
No 
motors 
14.9.1 
Endurance test on motors 
 
Page of 32