TU 970II (serv.man4) - Harman Kardon Audio EMC - CB Certificate (repair manual). Page 16

Read Harman Kardon TU 970II (serv.man4) EMC - CB Certificate online

Page 14 of 24 
Report Reference No.: CPSA0106916 
 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
Test Report EN 60065E Rev. 00 / 2004-09 
 
 
Accessible conductive parts of Class I equipment 
reliably connected to earth terminal, within 
equipment 
Class II apparatus 
 
Class I supply equipment with non-hazardous live 
output voltage: output circuit not connected to earth
 N 
 
Protective earth conductors correctly coloured 
 
 
Equipment with non-detachable mains cord 
provided with separate protective earth terminal 
near mains input 
 N 
 
Protective earth terminal resistant to corrosion 
 
 
Earth resistance  test: < 0,1 
Ω at 25 A  ................... :  N 
15.3 
Terminals for external flexible cords and for 
permanent connection to the mains supply 
 N 
15.3.1 
Adequate terminals for connection of permanent 
wiring 
 N 
15.3.2 
Reliable connection of non-detachable cords: 
 
 
Not soldered to conductors of a printed circuit 
board 
 P 
 
Adequate clearances and creepage distances 
between connections should a wire break away 
 P 
 
Wire secured by additional means to the conductor  
15.3.3 
Screws and nuts clamping conductors have 
adequate threads: ISO 261, ISO 262 or similar 
 N 
15.3.4 
Soldered conductors wrapped around terminal 
prior to soldering or held in place by additional 
means 
 N 
 
Clamping of conductor and insulation if not 
soldered or held by screws 
 P 
15.3.5 
Terminals allow connection of appropriate cross-
sectional area of conductors, for the rated current 
of the equipment 
 P 
15.3.6 
Terminals to 15.3.3 have sizes required by table 16  
15.3.7 
Terminals clamp conductors between metal and 
have adequate pressure 
 P 
 
Terminals designed to avoid conductor slipping out 
when tightened or loosened 
 P 
 
Terminals adequately fixed to avoid loosening 
when the clamping is tightened or loosened and 
stress on internal wiring is avoided 
 P 
15.3.8 
Terminals carrying a current more than 0,2 A: 
contact pressure not transmitted by insulating 
material except ceramic 
No contact pressure 
15.3.9 
Termination of non-detachable cords: wires 
terminated near to each other 
 P 
Page of 32
Display