Page 6 of 24
Report Reference No.: CPSA0106916
Clause
Requirement – Test
Result - Remark
Verdict
Test Report EN 60065E Rev. 00 / 2004-09
Reinforced or double insulation being bridged with
2 capacitors in series complying with 14.2.1 a)
2 capacitors in series complying with 14.2.1 a)
N
Reinforced or double insulation being bridged with
a single capacitor complying with 14.2.1 b)
a single capacitor complying with 14.2.1 b)
N
Basic insulation bridged by components complying
with 14.3.4.3
with 14.3.4.3
N
8.7
Basic insulation between parts at 35 V to 71 V
(peak) a.c. or 60 V to 120 V d.c. and accessible
parts
(peak) a.c. or 60 V to 120 V d.c. and accessible
parts
No such voltage
N
Reinforced or double insulation between circuits
operating at voltages between 35 V and 71 V
(peak) a.c. or between 60 V and 120 V d.c. and
hazardous live parts at higher voltage
operating at voltages between 35 V and 71 V
(peak) a.c. or between 60 V and 120 V d.c. and
hazardous live parts at higher voltage
No such voltage
N
Separation by Class II isolating transformer
T901 P
Separation by Class I transformer
N
Separation by earthed conductive part
N
8.8
Basic or supplementary insulation > 0,4 mm (mm) :
N
Reinforced insulation > 0,4 mm (mm) .................... : Transformer bobbin:
0,86 mm
P
Thin sheet insulation
Insulation tape in T901
P
Basic or supplementary insulation, at least two
layers, each meeting 10.3
layers, each meeting 10.3
N
Basic or supplementary insulation, three layers any
two of which meet 10.3
two of which meet 10.3
N
Reinforced insulation, two layers each of which
meet 10.3
meet 10.3
N
Reinforced insulation, three layers any two which
meet 10.3
meet 10.3
N
8.9
Adequate insulation between internal hazardous
live conductors and accessible parts
live conductors and accessible parts
Double insulated
P
Adequate insulation between internal hazardous
live parts and conductors connected to accessible
parts
live parts and conductors connected to accessible
parts
P
8.10
Double insulation between conductors connected
to the mains and accessible parts
to the mains and accessible parts
P
8.11
Detaching of wires
P
No undue reduction of creepages or clearance
distances if wires become detached
distances if wires become detached
Primary wires in external cords
connected with multi-contact-
housing
connected with multi-contact-
housing
P
Vibration test carried out ......................................... : See clause 12.1.2
P
8.12
Adequate cross-sectional area of internal wiring to
mains socket-outlets
mains socket-outlets
No mains socket-outlets
N