Page 7 of 24
Report Reference No.: CPSA0106916
Clause
Requirement – Test
Result - Remark
Verdict
Test Report EN 60065E Rev. 00 / 2004-09
8.13
Adequate fastening of windows, lenses, lamp
covers etc. (pull test 20 N for 10 s)
covers etc. (pull test 20 N for 10 s)
No accessible live part by user
P
8.14
Adequate fastening of covers (pull test 50 N for
10 s)
10 s)
No such covers
N
8.15
No risk of damage to the insulation of internal
wiring due to hot parts or sharp edges
wiring due to hot parts or sharp edges
No risk of damage
P
8.16
Only special supply equipment can be used
N
8.17
Insulated winding wire without additional
interleaved insulation
interleaved insulation
N
8.18
Endurance test as required by 8.17
N
8.19
Disconnection from the mains
P
8.19.1
Disconnect device
Mains plug used.
P
All-pole switch or circuit breaker with >3mm contact
separation
separation
N
8.19.2
Mains switch ON indication
P
8.20
Switch not fitted in the mains cord
P
8.21
Bridging components comply with clause 14
P
9
ELECTRIC SHOCK HAZARD UNDER NORMAL OPERATING CONDITIONS
⎯
9.1
Testing on the outside
P
9.1.1
For voltages >1000 V ac or >1500 V dc complies
with clause 13.3.1 for basic insulation
with clause 13.3.1 for basic insulation
N
9.1.1.1
Touch current measured from terminal devices
using the network in annex D ................................. :
using the network in annex D ................................. :
U1: 2,72 Vp
U2: 0,03 Vp
U2: 0,03 Vp
P
Discharge not exceeding 45 μC
N
Energy of discharge not exceeding 350 mJ
N
9.1.1.2
Test with test finger and test probe
Both test probe B and probe 13
of IEC 61032
of IEC 61032
P
9.1.2
No hazardous live shafts of knobs, handles or
levers
levers
N
9.1.3
Ventilation holes and other holes tested by means
of 4 mm x 100 mm test pin
of 4 mm x 100 mm test pin
Test pin didn’t touch live parts
P
9.1.4
Terminal devices tested with 1 mm x 20 mm test
pin (10 N); test probe D of IEC 61032
pin (10 N); test probe D of IEC 61032
P
Terminal devices tested with 1 mm x 100 mm
straight wire (1 N); test probe D of IEC 61032
straight wire (1 N); test probe D of IEC 61032
P
9.1.5
Pre-set controls tested with 2.5 mm x 100 mm test
pin (10 N); test probe C of IEC 61032
pin (10 N); test probe C of IEC 61032
No pre-set controls
N
9.1.6
No shock hazard due to stored charge on
withdrawal of the mains plug; voltage (V) after 2 s :
withdrawal of the mains plug; voltage (V) after 2 s :
N
If C is not greater than 0,1 μF no test needed
0,1 μF P
9.1.7
Enclosure sufficiently resistant to external force
P