Report Reference No.: CPSA0106916 
 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
Test Report EN 60065E Rev. 00 / 2004-09 
 
8.13 
Adequate fastening of windows, lenses, lamp 
covers etc. (pull test 20 N for 10 s) 
No accessible live part by user 
8.14 
Adequate fastening of covers (pull test 50 N for 
10 s) 
No such covers 
8.15 
No risk of damage to the insulation of internal 
wiring due to hot parts or sharp edges 
No risk of damage 
8.16 
Only special supply equipment can be used 
 
8.17 
Insulated winding wire without additional 
interleaved insulation 
 N 
8.18 
Endurance test as required by 8.17 
 
8.19 
Disconnection from the mains 
 
8.19.1 
Disconnect device 
Mains plug used. 
 
All-pole switch or circuit breaker with >3mm contact 
separation 
 N 
8.19.2 
Mains switch ON indication 
 
8.20 
Switch not fitted in the mains cord 
 
8.21 
Bridging components comply with clause 14 
 
ELECTRIC SHOCK HAZARD UNDER NORMAL OPERATING CONDITIONS 
⎯ 
9.1 
Testing on the outside 
9.1.1 
For voltages >1000 V ac or >1500 V dc complies 
with clause 13.3.1 for basic insulation  
 N 
9.1.1.1 
Touch current measured from terminal devices 
using the network in annex D ................................. :
U1: 2,72 Vp 
U2: 0,03 Vp 
 
Discharge not exceeding 45 μC  
 
Energy of discharge not exceeding 350 mJ 
 
9.1.1.2 
Test with test finger and test probe 
Both test probe B and probe 13 
of IEC 61032 
9.1.2 
No hazardous live shafts of knobs, handles or 
levers 
 N 
9.1.3 
Ventilation holes and other holes tested by means 
of 4 mm x 100 mm test pin 
Test pin didn’t touch live parts 
9.1.4 
Terminal devices tested with 1 mm x 20 mm test 
pin (10 N); test probe D of IEC 61032 
 P 
 
Terminal devices tested with 1 mm x 100 mm 
straight wire (1 N); test probe D of IEC 61032 
 P 
9.1.5 
Pre-set controls tested with 2.5 mm x 100 mm test 
pin (10 N); test probe C of IEC 61032 
No pre-set controls 
9.1.6 
No shock hazard due to stored charge on 
withdrawal of the mains plug; voltage (V) after 2 s  :
 N 
 
If C is not greater than 0,1 μF no test needed 
0,1 μF P 
9.1.7 
Enclosure sufficiently resistant to external force 
 
Page of 32