TU 970II (serv.man3) - Harman Kardon Audio EMC - CB Certificate (repair manual). Page 80

Read Harman Kardon TU 970II (serv.man3) EMC - CB Certificate online

 
 
 
EMC 
Compliance
 
Ltd. 
82-1 JEIL-RI, YANGJI-MYUN, YONGIN-CITY, KYUNGGI-DO, 449-825,  KOREA                                     
TEL:    82 31 336 9919      FAX :    82 31 336 4767 
This test report shall not be reproduced except in full, Without the written approval.
 
Report No.: EMC-CE-0857 
Page :            12        of      22
7
 
 
6.1.3  Test Data 
 
Test Specification : EN 61000-4-2 
Required Criterion: B 
 
Kind of Discharges 
 Contact Discharge   
 Air Discharge 
 HCP   
 VCP 
 
Discharge Voltages 
  Contact Discharge    : ± 2, 4 kV 
 Air Discharge       : ± 2, 4, 8 kV 
 
Discharge Impedance 
 330 Ω/150㎊               
 2KΩ/330㎊ 
 
Number Of Discharge 
 
Number of discharges per point, for each voltage and polarity 
      : 10 (Interval between discharges : ≥ 1s) 
 
Test point    ( Please refer to attached photograph. ) 
▪Contact Discharge : EUT Case, Screw, AV Cable Port, FM Tuner Coaxial Port 
DAM Port 
▪Air Discharge : Power Switch, Control Switch, Tuner Switch 
 
Test Results 
  Complied [A]                                     
 Not complied 
 
Comment  : 
- There was no change of operation status during above testing. 