Read Harman Kardon TU 970II (serv.man3) EMC - CB Certificate online
EMC
Compliance
Ltd.
82-1 JEIL-RI, YANGJI-MYUN, YONGIN-CITY, KYUNGGI-DO, 449-825, KOREA
TEL: 82 31 336 9919 FAX : 82 31 336 4767
This test report shall not be reproduced except in full, Without the written approval.
Report No.: EMC-CE-0857
Page : 12 of 22
7
6.1.3 Test Data
Test Specification : EN 61000-4-2
Required Criterion: B
Kind of Discharges
Contact Discharge
Air Discharge
HCP
VCP
Air Discharge
HCP
VCP
Discharge Voltages
Contact Discharge : ± 2, 4 kV
Air Discharge : ± 2, 4, 8 kV
Air Discharge : ± 2, 4, 8 kV
Discharge Impedance
330 Ω/150㎊
2KΩ/330㎊
Number Of Discharge
Number of discharges per point, for each voltage and polarity
: 10 (Interval between discharges : ≥ 1s)
Test point ( Please refer to attached photograph. )
▪Contact Discharge : EUT Case, Screw, AV Cable Port, FM Tuner Coaxial Port
Test point ( Please refer to attached photograph. )
▪Contact Discharge : EUT Case, Screw, AV Cable Port, FM Tuner Coaxial Port
DAM Port
▪Air Discharge : Power Switch, Control Switch, Tuner Switch
Test Results
Test Results
Complied [A]
Not complied
Comment :
- There was no change of operation status during above testing.