7
6.3 Electric Fast Transient/BURST
6.3.1 Measurement procedure
A ground reference plane was located on the floor.
EFT generator was connected to reference ground plane via low impedance
connection.
For floor standing equipment, EUT was placed on a 0.8 m wooden table.
For tabletop equipment, EUT was placed on a wooden table(0.8m)
above the reference plane.
6.3.2 Used equipments
Equipment
Model No.
Serial No.
Makers
Next
Cal. date
Used
UCS 500 M6 V0545100858
EM TEST
06.12.19
RWG500 M6
0701-08
EM TEST
06.05.08
EFT/B Tester
TSS500 M4
0402-01
EM TEST
06.05.03
Capacitive
coupling clamp
N/A N/A
EM