This test report shall not be reproduced except in full, Without the written approval.
 
Report No.: EMC-CE-0857 
Page :            14        of      22
7
 
 
6.2  Radio Frequency Electromagnetic Fields 
 
6.2.1  Measurement procedure 
 
The test was performed at 3m full anechoic chamber. 
For floor standing equipment, the EUT was standing on the floor. 
For tabletop equipment, the EUT was located on a wooden table 0.8m above the 
floor.  
The EUT was tested all sides, horizontal and vertical polarization. 
The field uniformity was calibrated for 1V/m, 3V/m, 10V/m. 
 
 
6.2.2  Used equipments 
 
Equipment 
Model no. 
Serial no. 
Makers 
Next Cal. 
date 
Used 
Power meter 
PM2002 
302852 
AR 
07.05.03 
 
Field monitor 
FM5004 
303078 
AR 
07.05.09 
 
Power sensor 
(with adapter) 
PH2000 303224 AR 
07.05.03  
Power sensor 
(with adapter) 
PH2000 303222 AR 
07.05.03  
Isotropic probe 
FP5000 
303057 
AR 
07.12.08 
 
Directional 
coupler 
DC6180 303976 AR 
07.05.03  
Amplifier 150W1000M2 303843  AR 07.05.03   
Signal generator 
2023A 
202304/2578 IFR  07.05.03 
 
Function generator 
33120A 
US36018826 
HP 
07.05.03 
 
BiconiLog Ant. 
3142B 
1786 
EMCO 
07.05.15 
 
 
 
6.2.3  Measurement uncertainty  
 
Radio Frequency Electromagnetic Fields    : ± 0.206 [dB](k=2, 95%) 
 