This test report shall not be reproduced except in full, Without the written approval.
Report No.: EMC-CE-0857
Page : 14 of 22
7
6.2 Radio Frequency Electromagnetic Fields
6.2.1 Measurement procedure
The test was performed at 3m full anechoic chamber.
For floor standing equipment, the EUT was standing on the floor.
For tabletop equipment, the EUT was located on a wooden table 0.8m above the
floor.
The EUT was tested all sides, horizontal and vertical polarization.
The field uniformity was calibrated for 1V/m, 3V/m, 10V/m.
6.2.2 Used equipments
Equipment
Model no.
Serial no.
Makers
Next Cal.
date
Used
Power meter
PM2002
302852
AR
07.05.03
Field monitor
FM5004
303078
AR
07.05.09
Power sensor
(with adapter)
PH2000 303224 AR
07.05.03
Power sensor
(with adapter)
PH2000 303222 AR
07.05.03
Isotropic probe
FP5000
303057
AR
07.12.08
Directional
coupler
DC6180 303976 AR
07.05.03
Amplifier 150W1000M2 303843 AR 07.05.03
Signal generator
2023A
202304/2578 IFR 07.05.03
Function generator
33120A
US36018826
HP
07.05.03
BiconiLog Ant.
3142B
1786
EMCO
07.05.15
6.2.3 Measurement uncertainty
Radio Frequency Electromagnetic Fields : ± 0.206 [dB](k=2, 95%)