EMC 
Compliance
 
Ltd. 
82-1 JEIL-RI, YANGJI-MYUN, YONGIN-CITY, KYUNGGI-DO, 449-825,  KOREA                                     
TEL:    82 31 336 9919      FAX :    82 31 336 4767 
This test report shall not be reproduced except in full, Without the written approval.
 
Report No.: EMC-CE-0857 
Page :            11        of      22
7
 
 
6.  Test results 
 
6.1  Electrostatic Discharge 
 
6.1.1  Measurement procedure 
 
A ground reference plane was located on the floor, and connected to earth via a   
low impedance connection. 
The return cable of the ESD generator was connected to the reference plane. In 
case of floor standing equipment, EUT was placed on the reference plane on 0.1 
m of insulating Support. 
In case of table top equipment, EUT was placed on a wooden table 0.8m above 
the reference grounded floor. 
A horizontal coupling plane(HCP) was placed on the table, and 
Connected to the reference plane via a 470㏀  resistor located in each end 
(0.5mm insulating support between EUT and HCP). 
In both cases a vertical coupling plane(VCP) OF 0.5 X 0.5m was located 10cm 
from the EUT’s sides. 
The VCP was connected to the reference plane in the same matter as the HCP.   
 
         
6.1.2  Used equipments 
 
Equipment 
Model No. 
Serial No. 
Makers 
Next Cal. 
Date 
Used 
ESD Tester 
PESD1600 
H011309 
HAEFELY 
2006.08.12 
 
HCP -  -  - -  
VCP -  -  - -  
 