Read Harman Kardon TU 970II (serv.man3) EMC - CB Certificate online
EMC
Compliance
Ltd.
82-1 JEIL-RI, YANGJI-MYUN, YONGIN-CITY, KYUNGGI-DO, 449-825, KOREA
TEL: 82 31 336 9919 FAX : 82 31 336 4767
This test report shall not be reproduced except in full, Without the written approval.
Report No.: EMC-CE-0857
Page : 15 of 22
7
6.2.4 Test Data
Test Specification : EN 61000-4-3
Required Criterion: A
Frequency Range
Required Criterion: A
Frequency Range
80MHz - 1000MHz 895 MHz - 905MHz
26MHz - 500MHz
Test level
1V/m
3V/m
10V/m
Modulation
AM : 1kHz, 80%
PM : 1Hz (duty cycle 1/8, 217 Hz repetition frequency)
Frequency step
log 1% step
log 3% step
log 5% step
Dwell Time
3 s
2 s
1 s
Test point
Front
Rear
Left
Right
Rear
Left
Right
Test Results
Complied [A]
Not complied
Comment :
- There was no change of operation status during above testing.
Click on the first or last page to see other TU 970II (serv.man3) service manuals if exist.