TU 970II (serv.man3) - Harman Kardon Audio EMC - CB Certificate (repair manual). Page 83

Read Harman Kardon TU 970II (serv.man3) EMC - CB Certificate online

 
 
 
EMC 
Compliance
 
Ltd. 
82-1 JEIL-RI, YANGJI-MYUN, YONGIN-CITY, KYUNGGI-DO, 449-825,  KOREA                                     
TEL:    82 31 336 9919      FAX :    82 31 336 4767 
This test report shall not be reproduced except in full, Without the written approval.
 
Report No.: EMC-CE-0857 
Page :            15        of      22
7
 
 
6.2.4  Test Data 
 
Test Specification : EN 61000-4-3   
Required Criterion: A 
 
Frequency Range 
 80MHz - 1000MHz       895 MHz - 905MHz   
 26MHz - 500MHz 
 
Test level 
1V/m                                   
  3V/m                           
  10V/m 
 
Modulation 
 
AM : 1kHz, 80%         
  PM : 1Hz (duty cycle 1/8, 217 Hz repetition frequency) 
 
Frequency step   
  log 1% step                 
  log 3% step               
  log 5% step 
 
Dwell Time 
  3 s                                   
  2 s                                 
 1 s 
 
Test point 
  Front                     
 Rear 
 Left 
 Right 
 
Test Results 
  Complied [A]                                 
 Not complied 
 
Comment : 
- There was no change of operation status during above testing. 
 
 
 
Page of 90