Read Harman Kardon SOUNDSTICKS III (serv.man2) EMC - CB Certificate online
IEC 60950 (3rd)
- Page 3 of 6 -
www.nemko.com
Report No. 158002
2.6.101
Add this sub-clause:
Earthing of CLASS 0I EQUIPMENT
Plugs with a lead wire for earthing shall not be used for
equipment having a rated voltage exceeding 150V.
For plugs with a lead wire for earthing, the lead wire
shall not be earthed by a clip.
CLASS 0I EQUIPMENT shall be provided with an
earthing terminal or lead wire for earthing in the
external where easily visible.
Earthing of CLASS 0I EQUIPMENT
Plugs with a lead wire for earthing shall not be used for
equipment having a rated voltage exceeding 150V.
For plugs with a lead wire for earthing, the lead wire
shall not be earthed by a clip.
CLASS 0I EQUIPMENT shall be provided with an
earthing terminal or lead wire for earthing in the
external where easily visible.
Class III equipment
N/A
3.2.5
Delete 1) in Table 3B.
Considered. N/A
4.2.8
Add the following informative remark after the last
sentence.
Remark - IEC 61965 is also applicable instead of IEC
60065.
sentence.
Remark - IEC 61965 is also applicable instead of IEC
60065.
No CRTs in equipment.
N/A
4.5.1
Addition:
Add the following to suffix 5) as specified in
“Conditions applicable to Table 4A, Parts 1 and 2”.
“Conditions applicable to Table 4A, Parts 1 and 2”.
With regard to Table 4A, insulating materials
complying with Japanese requirements (refer to
Japanese differences for the current IEC 60335-1 (3rd
Edition) in CB Bulletin 101B) are also acceptable.
complying with Japanese requirements (refer to
Japanese differences for the current IEC 60335-1 (3rd
Edition) in CB Bulletin 101B) are also acceptable.
Add a suffix 7) in “Conditions applicable to Table 4A,
Parts 1 and 2”.
Parts 1 and 2”.
In the right column of Table 4A, Part 1, add suffix 7) to
“50” (K), corresponding to “- without T – marking” in
the left column so as to become “50 7)”.
“50” (K), corresponding to “- without T – marking” in
the left column so as to become “50 7)”.
Add 7) to Table 4A, Part 2 as follows.
7) This value shall apply only to wiring or cords
complying with relevant IEC standards. Others shall
comply with Japanese requirements (refer to Japanese
differences for the current IEC 60335-1 (3rd Edition) in
CB Bulletin 101B).
complying with relevant IEC standards. Others shall
comply with Japanese requirements (refer to Japanese
differences for the current IEC 60335-1 (3rd Edition) in
CB Bulletin 101B).
Considered. P
4.7.3.2
Add the following in 7
th
paragraph of this Sub-Clause.
-
for thin materials, e.g., flexible printed boards, etc.,
used inside equipment, be of FLAMMABILITY CLASS
VTM-2 or better.
VTM-2 or better.
Comply with the
requirement.
requirement.