IEC 60950 (3rd)
 
 
- Page 5 of 6 - 
 
 
www.nemko.com
 
Report No.   158002 
 
 
 
U.2.2 
Replace this Sub-Clause by: 
Test 8 of IEC 60851-3:1996, 5.1.1, using the 
mandrel diameters of table U.1. The test sample 
is then examined in accordance with IEC 60851-
3:1996, 5.1.1.4, followed by the test of 5.2.2 of 
this standard except applying the test voltage 
between the wire and the mandrel. A test voltage 
shall be the appropriate voltage in table 5B (see 
5.2.2) of this standard. However, the minimum 
values shall be as follows: 
for BASIC INSULATION or 
SUPPLEMENTARY INSULATION, 1500 V, 
or; 
-     for REINFORCED INSULATION, 3000 V. 
TIW not used. 
N/A 
     Table U.1 Table U.1 - Mandrel diameter 
 
Nominal Conductor 
diameter 
mm 
Mandrel diameter 
mm ± 0,2 mm 
0,05 – 0,34 
0.35 – 0,49 
0,50 – 0,74 
0,75 – 2,49 
2,50 – 5,00 
4,0 
6,0 
8,0 
10,0 
4 times of the diameter of 
conductor 
1)
 
1)
 in compliance with IEC 60317-43. 
The tension to be applied to the wire during 
winding on the mandrel is calculated from the 
wire diameter to be equivalent to 118 Mpa ± 10 % 
(118 N/mm
2
 ± 10 %). 
Table U.1 
Replacement: 
Mandrel diameter 
 
The tension to be applied to the wire during 
winding on the mandrel is calculated from the 
wire diameter to be equivalent to 118 Mpa ± 
10 % (118 N/mm2 ± 10 %). 