Read Harman Kardon SOUNDSTICKS III (serv.man2) EMC - CB Certificate online
IEC 60950 (3rd)
- Page 4 of 6 -
www.nemko.com
Report No. 158002
5.1.6
Replacement:
Replace Table 5A.
Replace Table 5A.
Class III equipment
N/A
5.3.8.2
Replacement:
Replace 3rd Item as follows.
Replace 3rd Item as follows.
- BASIC INSULATION between the PRIMARY
CIRCUIT and accessible conductive parts of
CLASS I or 0I EQUIPMENT;
CIRCUIT and accessible conductive parts of
CLASS I or 0I EQUIPMENT;
Class III equipment
N/A
Annex A
Add this Sub-Clause:
Flammability tests for classifying materials VTM
Flammability tests for classifying materials VTM
Thin sheet materials shall comply with ISO 9773.
Comply with the requirement.
P
Annex G
Add the following new note below Table G.1:
2. In Japan, MAINS TRANSIENT VOLTAGE for
equipment with a Nominal AC MAINS SUPPLY
VOLTAGE of 100V is to be decided based on the
column where Nominal AC MAINS SUPPLY
VOLTAGE in Table G.1 is 150V.
2. In Japan, MAINS TRANSIENT VOLTAGE for
equipment with a Nominal AC MAINS SUPPLY
VOLTAGE of 100V is to be decided based on the
column where Nominal AC MAINS SUPPLY
VOLTAGE in Table G.1 is 150V.
Not used.
N/A
Annex P
Add “IEC 61965:2000, Mechanical Safety for
Cathode Ray Tubes”.
Cathode Ray Tubes”.
CRT(s) not used in the equip
ment.
ment.
N/A
Annex U
Replace the second paragraph by:
This annex covers to round winding wires having
diameters between 0.05 mm and 5.00 mm.
This annex covers to round winding wires having
diameters between 0.05 mm and 5.00 mm.
See main test report.
N/A
U.2.1
Replace the text of this Sub-Clause by:
The test sample is prepared according to IEC
60851-5:1996, 4.4.1 (for a twisted pair). The
sample is then subjected to the test of 5.2.2 of
this standard, with a test voltage not less than
twice the appropriate voltage in table 5B (see
5.2.2) of this standard. However, the minimum
values shall be as follows:
The test sample is prepared according to IEC
60851-5:1996, 4.4.1 (for a twisted pair). The
sample is then subjected to the test of 5.2.2 of
this standard, with a test voltage not less than
twice the appropriate voltage in table 5B (see
5.2.2) of this standard. However, the minimum
values shall be as follows:
-
for BASIC INSULATION or
SUPPLEMENTARY INSULATION, 3000 V,
or;
SUPPLEMENTARY INSULATION, 3000 V,
or;
- for REINFORCED INSULATION, 6000 V.
TIW not used.
N/A