SOUNDSTICKS III (serv.man2) - Harman Kardon Audio EMC - CB Certificate (repair manual). Page 82

Read Harman Kardon SOUNDSTICKS III (serv.man2) EMC - CB Certificate online

IEC 60950 (3rd)
 
 
- Page 4 of 6 - 
 
 
www.nemko.com
 
Report No.   158002 
 
 
 
 
5.1.6 
Replacement: 
Replace Table 5A. 
 
Class III equipment 
N/A 
5.3.8.2 
Replacement: 
Replace 3rd Item as follows. 
- BASIC INSULATION between the PRIMARY 
CIRCUIT and accessible conductive parts of 
CLASS I or 0I EQUIPMENT; 
Class III equipment 
N/A 
Annex A 
 
Add this Sub-Clause:  
Flammability tests for classifying materials VTM 
Thin sheet materials shall comply with ISO 9773.
Comply with the requirement.
Annex G 
Add the following new note below Table G.1: 
2. In Japan, MAINS TRANSIENT VOLTAGE for 
equipment with a Nominal AC MAINS SUPPLY 
VOLTAGE of 100V is to be decided based on the 
column where Nominal AC MAINS SUPPLY 
VOLTAGE in Table G.1 is 150V. 
Not used. 
N/A 
Annex P 
Add “IEC 61965:2000, Mechanical Safety for 
Cathode Ray Tubes”. 
CRT(s) not used in the equip
ment. 
N/A 
Annex U 
Replace the second paragraph by: 
This annex covers to round winding wires having 
diameters between 0.05 mm and 5.00 mm. 
See main test report. 
N/A 
U.2.1 
Replace the text of this Sub-Clause by: 
The test sample is prepared according to IEC 
60851-5:1996, 4.4.1 (for a twisted pair). The 
sample is then subjected to the test of 5.2.2 of 
this standard, with a test voltage not less than 
twice the appropriate voltage in table 5B (see 
5.2.2) of this standard. However, the minimum 
values shall be as follows: 
for BASIC INSULATION or 
SUPPLEMENTARY INSULATION, 3000 V, 
or; 
-     for REINFORCED INSULATION, 6000 V. 
TIW not used. 
N/A 