Read Harman Kardon SB 16 (serv.man9) EMC - CB Certificate online
Clause
Requirement - Test
Result - Remark
Verdict
TÜV SÜD Product Service GmbH
Report reference No.:081-61102-000
Electrical Safety
F10Y2-X dev.DOC
Ridlerstr. 65
2006-11-02
D-80339 München
Page 4 of 52
Test Report National land Group Differences IEC 60065 7
th
Ed. Rev. 00 / 2006-02
AU
Annex ZZ
(normative)
Variations to IEC 60065:2001 for application
in Australia and New Zealand
⎯
ZZ.1 Introduction This Annex sets out variations between this Standard and IEC
60065:2001. These variations indicate national variations for purposes of the
IECEE CB Scheme and will be published in the IECEE CB Bulletin. These
variations are indicated within the body of the Standard by shading and
strikethrough.
60065:2001. These variations indicate national variations for purposes of the
IECEE CB Scheme and will be published in the IECEE CB Bulletin. These
variations are indicated within the body of the Standard by shading and
strikethrough.
ZZ.2 Variations The variations are as follows:
⎯
7.1.5
In Table 3 under item c) add an h) in both
columns against ‘thermoplastic materials’ and
add the following
new footnote:
h As an alternative to the method described in
footnote f) the following variation may be used
where there is any doubt about the suitability of
the material:
columns against ‘thermoplastic materials’ and
add the following
new footnote:
h As an alternative to the method described in
footnote f) the following variation may be used
where there is any doubt about the suitability of
the material:
The ball-pressure test described in AS/NZS
60695.10.2 may be carried out.
60695.10.2 may be carried out.
To assess compliance under normal operating
conditions, the test shall be made in a heating
cabinet at a temperature of 40°C ±2°C plus the
maximum temperature rise determined under
normal operating conditions but, it shall be at
least
conditions, the test shall be made in a heating
cabinet at a temperature of 40°C ±2°C plus the
maximum temperature rise determined under
normal operating conditions but, it shall be at
least
-for external parts 75°C ±2°C
-for materials supporting parts conductively
connected to the mains 125°C ±2°C
connected to the mains 125°C ±2°C
Not applied for.
N
7.2
After the second paragraph, add the following:
The alternative method described in footnote h)
of Table 3 may be used.
The alternative method described in footnote h)
of Table 3 may be used.
Ditto. N
15.1.1
After the second paragraph, add the following:
Plugs for the connection of apparatus to mains-
powered socket-outlets shall comply with
AS/NZS 3112 or AS/NZS 3123. Apparatus with a
plug portion, suitable for insertion into a 10 A 3-
pin flat-pin socket-outlet complying with AS/NZS
3112, shall comply with the requirements of
AS/NZS 3112 for equipment with integral pins for
insertion into socket-outlets.
Plugs for the connection of apparatus to mains-
powered socket-outlets shall comply with
AS/NZS 3112 or AS/NZS 3123. Apparatus with a
plug portion, suitable for insertion into a 10 A 3-
pin flat-pin socket-outlet complying with AS/NZS
3112, shall comply with the requirements of
AS/NZS 3112 for equipment with integral pins for
insertion into socket-outlets.
It should be considered when
national approval.
national approval.
N
15.3.5
In Table 15, in the second and third rows of the
first column replace ‘6’ with ‘7.5’.
first column replace ‘6’ with ‘7.5’.
N
Click on the first or last page to see other SB 16 (serv.man9) service manuals if exist.