Page 11 of 54 Report No. SH09061297-001
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No: IEC/EN 60065H
TRF originator Intertek ETL SEMKO SH
12.1.2 Vibration
test
Not carried out. As no
connection or part, which might
impair safety, can become
loose.
connection or part, which might
impair safety, can become
loose.
Pass
12.1.3
Impact hammer test
0.5J applied to the whole
enclosure, no hazard.
enclosure, no hazard.
Pass
Steel ball test
Pass
12.1.4
Drop test for portable apparatus where mass < 7
kg
kg
N/A
12.1.5
Thermoplastic enclosures stress relief test
N/A
12.2
Fixing of knobs, push buttons, keys and levers
No damage after test with
100N periphery torque or axial
pull force.
100N periphery torque or axial
pull force.
Pass
12.3
Remote controls with hazardous live parts
N/A
12.4
Drawers (pull test 50 N, 10 s)
No drawer is provided
N/A
12.5
Antenna coaxial sockets providing isolation
No antenna coaxial socket is
provided.
provided.
N/A
12.6
Telescoping or rod antennas construction
No such device.
N/A
12.6.1
Telescoping or rod antennas securement
No such device.
N/A
13
CLEARANCE AND CREEPAGE DISTANCES
13.1
Clearances in accordance with 13.3
Pass
Creepage distances in accordance with 13.4
Pass
13.2
Determination of operating voltage
Pass
13.3
Clearances
(see appended table)
Pass
13.3.2
Circuits conductively connected to the mains
comply with table 8 and, where applicable, table 9
comply with table 8 and, where applicable, table 9
(see appended table)
Pass
13.3.3
Circuits not conductively connected to the mains
comply with table 10
comply with table 10
N/A
13.4
Creepage distances
(see appended table)
Pass
Creepage distances greater than table 11 minima (see appended table)
Pass
13.5
Printed boards
No such printed board used.
N/A
13.5.1
Clearances and creepage distances between
conductors on printed circuit boards, one of which
may be conductively connected to the mains, as in
fig. 10
conductors on printed circuit boards, one of which
may be conductively connected to the mains, as in
fig. 10
N/A