MAS 100-110 (serv.man2) - Harman Kardon Audio EMC - CB Certificate (repair manual). Page 14

Read Harman Kardon MAS 100-110 (serv.man2) EMC - CB Certificate online

 
                                                                      Page 14 of 54                           Report No. SH09061297-001 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No:  IEC/EN 60065H 
 
       TRF originator Intertek ETL SEMKO SH 
 
 
14.4.1 
High voltage transformers and multipliers tested as 
part of the submission 
 
N/A 
14.4.2 
High voltage assemblies and other parts tested as 
part of the submission 
 
N/A 
14.5 
Protective devices 
See below 
Pass 
 
Protective devices used within their ratings 
Fuse FH1: T5AL 250V 
Pass 
 
External clearances and creepage distances meet 
requirement of clause 13 for the voltage across the 
device when opened 
(see appended table) 
Pass 
14.5.1.1 
a) Thermal cut-outs separately approved 
 
N/A 
 
b) Thermal cut-outs tested as part of the 
submission 
 N/A 
14.5.1.2 
a) Thermal links separately approved 
 
N/A 
 
b) Thermal links tested as part of the submission 
 
N/A 
14.5.1.3 
Thermal devices re-settable by soldering 
 
N/A 
14.5.2.1 
Fuse-links in the mains circuit according to IEC 
60127 
 Pass 
14.5.2.2 
Correct marking of fuse-links adjacent to holder ... : Fuse FH1: T5AL 250V 
Pass 
14.5.2.3 
Not possible to connect fuses in parallel ............... : The fuse holder is so designed 
that fuse-links can not be 
connected in parallel. 
Pass 
14.5.2.4 
Not possible to touch hazardous live parts when 
replacing fuse-links without the use of a tool ......... :
The fuse holder is so designed 
that not possible to touch 
hazardous live parts when 
replacing fuse-links without the 
use of a tool. 
Pass 
14.5.3 
PTC-S thermistors comply with IEC 60730-1 
No PTC used. 
N/A 
 
PTC-S devices (15 W) category V-1 or better 
 
N/A 
14.5.4 Circuit 
protectors 
have adequate breaking capacity 
and their position is correctly marked 
 N/A 
14.6 
Switches 
No switch used. 
N/A 
14.6.1 a) 
Separate testing to IEC 61058 including: 
10 000 operations 
Normal pollution suitability 
Resistance to heat and fire level 3 
and 
V-0 compliance with annex G, G.1.1 
 
N/A 
Page of 54
Display