Page 6 of 54 Report No. SH09061297-001
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No: IEC/EN 60065H
TRF originator Intertek ETL SEMKO SH
5.4.2
Disconnect device: plug/coupler or all-pole mains
switch location, accessibility and markings
switch location, accessibility and markings
The appliance coupler is acting
as disconnect device. The
manual has suitable statement.
as disconnect device. The
manual has suitable statement.
Pass
Instructions for permanently connected equipment Not permanently connected
equipment.
N/A
6 HAZARDOUS
RADIATION
6.1
Ionizing radiation < 36 pA/kg (0,5 mR/h)
No ionizing radiation.
N/A
6.1
EN 60065
European Council Directive 96/29/Euratom of 13
May 1996 10cm from outer surface of apparatus
<1µSv/h (0,1mR/h)
May 1996 10cm from outer surface of apparatus
<1µSv/h (0,1mR/h)
N/A
6.2
Laser radiation, emission limits to IEC 60825-1 .... : Class 1 Laser
Pass
Emission limits under fault conditions .................... : Class 1 Laser
Pass
7
HEATING UNDER NORMAL OPERATING CONDITIONS
7.1
Temperature rises not exceeding specified values,
no operation of fuse links
no operation of fuse links
(see appended table)
Pass
7.1.1
Temperature rise of accessible parts
(see appended table)
Pass
7.1.2
Temperature rise of parts providing electrical
insulation
insulation
(see appended table)
Pass
7.1.3
Temperature rise of parts acting as a support or as
a mechanical barrier
a mechanical barrier
(see appended table)
Pass
7.1.4
Temperature rise of windings
(see appended table)
Pass
7.1.5
Parts not subject to a limit under 7.1.1 to 7.1.4
(see appended table)
Pass
7.2
Softening temperature of insulating material
supporting parts conductively connected to the
mains carrying a current > 0,2 A at least 150
supporting parts conductively connected to the
mains carrying a current > 0,2 A at least 150
o
C
(see appended table)
Pass
8
CONSTRUCTIONAL REQUIREMENTS WITH REGARD TO THE PROTECTION
AGAINST ELECTRIC SHOCK
AGAINST ELECTRIC SHOCK
8.1
Conductive parts covered by lacquer, paper,
untreated textile oxide films and beads etc.
considered to be bare
untreated textile oxide films and beads etc.
considered to be bare
Windings and PCB are
covered by lacquer and
considered to be bare.
covered by lacquer and
considered to be bare.
Pass
8.2
No shock hazard when changing voltage setting
device, fuse-links or handling drawers etc.
device, fuse-links or handling drawers etc.
Tools required.
Pass
8.3
Insulation of hazardous live parts not provided by
hygroscopic material
hygroscopic material
Pass
Click on the first or last page to see other MAS 100-110 (serv.man2) service manuals if exist.