MAS 100-110 (serv.man2) - Harman Kardon Audio EMC - CB Certificate (repair manual). Page 8

Read Harman Kardon MAS 100-110 (serv.man2) EMC - CB Certificate online

 
                                                                      Page 8 of 54                           Report No. SH09061297-001 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No:  IEC/EN 60065H 
 
       TRF originator Intertek ETL SEMKO SH 
 
 
 
Basic or supplementary insulation, at least two 
layers, each meeting 10.3 
 N/A 
 
Basic or supplementary insulation, three layers any 
two of which meet 10.3 
 N/A 
 
Reinforced insulation, two layers each of which 
meet 10.3 
Two layers of insulating tape 
provided between primary 
winding and secondary 
winding of transformer, each 
layer comply with the 
requirement of 10.3. 
Pass 
 
Reinforced insulation, three layers any two which 
meet 10.3 
 N/A 
8.9 
Adequate insulation between internal hazardous 
live conductors and accessible parts 
Primary wiring: min. 0.4mm 
Pass 
 
Adequate insulation between internal hazardous 
live parts and conductors connected to accessible 
parts 
 Pass 
8.10 
Double insulation between conductors connected 
to the mains and accessible parts 
 Pass 
8.11 
Detaching of wires 
 
Pass 
 
No undue reduction of creepages or clearance 
distances if wires become detached 
All wires are fixed by double 
securement. 
Pass 
 Vibration 
test carried out  ........................................ : No, no need. 
N/A 
8.12 Void 
 
 
N/A 
8.13 
Adequate fastening of windows, lenses, lamp 
covers etc. (pull test 20 N for 10 s) 
 N/A 
8.14 
Adequate fastening of covers (pull test 50 N for 
10 s) 
Fastened by metal screws. 
Pass 
8.15 
No risk of damage to the insulation of internal 
wiring due to hot parts or sharp edges 
The internal lead wires are 
secured away from the hot 
parts and sharp edges by the 
construction. 
Pass 
8.16 
Only special supply equipment can be used 
 
N/A 
8.17 
Insulated winding wire without additional 
interleaved insulation 
 N/A 
8.18 
Endurance test as required by 8.17 
 
N/A 
8.19 
Disconnection from the mains 
See below. 
Pass 
8.19.1 Disconnect 
device 
Appliance coupler is used as 
the disconnect device. 
Pass 