Page 8 of 54 Report No. SH09061297-001
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No: IEC/EN 60065H
TRF originator Intertek ETL SEMKO SH
Basic or supplementary insulation, at least two
layers, each meeting 10.3
layers, each meeting 10.3
N/A
Basic or supplementary insulation, three layers any
two of which meet 10.3
two of which meet 10.3
N/A
Reinforced insulation, two layers each of which
meet 10.3
meet 10.3
Two layers of insulating tape
provided between primary
winding and secondary
winding of transformer, each
layer comply with the
requirement of 10.3.
provided between primary
winding and secondary
winding of transformer, each
layer comply with the
requirement of 10.3.
Pass
Reinforced insulation, three layers any two which
meet 10.3
meet 10.3
N/A
8.9
Adequate insulation between internal hazardous
live conductors and accessible parts
live conductors and accessible parts
Primary wiring: min. 0.4mm
Pass
Adequate insulation between internal hazardous
live parts and conductors connected to accessible
parts
live parts and conductors connected to accessible
parts
Pass
8.10
Double insulation between conductors connected
to the mains and accessible parts
to the mains and accessible parts
Pass
8.11
Detaching of wires
Pass
No undue reduction of creepages or clearance
distances if wires become detached
distances if wires become detached
All wires are fixed by double
securement.
securement.
Pass
Vibration
test carried out ........................................ : No, no need.
N/A
8.12 Void
N/A
8.13
Adequate fastening of windows, lenses, lamp
covers etc. (pull test 20 N for 10 s)
covers etc. (pull test 20 N for 10 s)
N/A
8.14
Adequate fastening of covers (pull test 50 N for
10 s)
10 s)
Fastened by metal screws.
Pass
8.15
No risk of damage to the insulation of internal
wiring due to hot parts or sharp edges
wiring due to hot parts or sharp edges
The internal lead wires are
secured away from the hot
parts and sharp edges by the
construction.
secured away from the hot
parts and sharp edges by the
construction.
Pass
8.16
Only special supply equipment can be used
N/A
8.17
Insulated winding wire without additional
interleaved insulation
interleaved insulation
N/A
8.18
Endurance test as required by 8.17
N/A
8.19
Disconnection from the mains
See below.
Pass
8.19.1 Disconnect
device
Appliance coupler is used as
the disconnect device.
the disconnect device.
Pass