Read Harman Kardon MAS 100-110 (serv.man2) EMC - CB Certificate online
Page 1 of 54 Report No. SH09061297-001
TRF No: IEC/EN 60065H
TRF originator Intertek ETL SEMKO SH
TEST REPORT
IEC/EN 60065
Audio, video and similar electronic apparatus
Safety requirements
Report
Reference No. ....................... : SH09061297-001
Tested by (+ signature)...................... : Jacky Shu
.....................................................
Approved by (+ signature) ................. : Justin Yu
.....................................................
Date of issue ...................................... : July 10, 2009
Contents ............................................. : 54 pages
CB Testing Laboratory
Contents ............................................. : 54 pages
CB Testing Laboratory
................... : Intertek Testing Services Shanghai Ltd.
Address ............................................. : Building No.86, 1198 Qinzhou Road (North), Shanghai 200233,
China
Testing location/procedure ................ : CBTL RMT
SMT
WMT
TMP
Testing location/address.................... : As above
Applicant' s name .............................. : Harman Consumer Group Inc.
Address ............................................. : 8500 Balboa Blvd. Northridge, CA 91329, USA
Test specification:
Applicant' s name .............................. : Harman Consumer Group Inc.
Address ............................................. : 8500 Balboa Blvd. Northridge, CA 91329, USA
Test specification:
Standard............................................. : IEC 60065_2001+ A1_2005. Group- and national differences for the
CENELEC countries (EN60065:2002+A1_2006).
Test procedure .................................. : CB, CE LVD, S mark
Non-standard test method ................ : N/A
Test Report Form/blank test report
Test Report Form No. ........................ : TTRF IECEN60065H
TRF originator. ................................... : Intertek ETL SEMKO SH
Master TRF ........................................ : Dated 2006-08
Copyright © 2006 IEC System for Conformity Testing and Certification of Electrical Equipment
(IECEE), Geneva, Switzerland. All rights reserved.
(IECEE), Geneva, Switzerland. All rights reserved.
This publication may be reproduced in whole or in part for non-commercial purposes as long as the IECEE is
acknowledged as copyright owner and source of the material. IECEE takes no responsibility for and will not assume
liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and
context.
acknowledged as copyright owner and source of the material. IECEE takes no responsibility for and will not assume
liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and
context.
Page 2 of 54 Report No. SH09061297-001
TRF No: IEC/EN 60065H
TRF originator Intertek ETL SEMKO SH
Test item Description ......................... : CD Micro
Trademark .......................................... : Harman/kardon
Model and/or type reference.............. : MAS100, MAS110
Manufacturer ...................................... : Jiang Men KeYi Electronic Ltd.
#180 West High & New Technology Road, JiangHai Region, JiangMen,
GuangDong, China
GuangDong, China
Factory ............................................... : Jiang Men KeYi Electronic Ltd.
#180 West High & New Technology Road, JiangHai Region, JiangMen,
GuangDong, China
GuangDong, China
Rating(s)............................................. : 100-240V~, 50/60Hz, 300W Class II
Page 3 of 54 Report No. SH09061297-001
TRF No: IEC/EN 60065H
TRF originator Intertek ETL SEMKO SH
Copy of marking plate
Model MAS110
Model MAS110
Note: The marking plate of model MAS100 is same as model MAS110 except model name.
Summary of Testing and Conclusions:
From the result of our examination and tests in the submitted samples, conclude they comply with the
requirements of the standard IEC 60065:2001+A1:2005 and EN 60065_2002+A1_2006.
From the result of our examination and tests in the submitted samples, conclude they comply with the
requirements of the standard IEC 60065:2001+A1:2005 and EN 60065_2002+A1_2006.
Page 4 of 54 Report No. SH09061297-001
TRF No: IEC/EN 60065H
TRF originator Intertek ETL SEMKO SH
Test case verdicts
Test case does not apply to the test object.................. : N/A (not applicable)
Test item does meet the requirement .......................... : Pass
Test item does not meet the requirement .................... : Fail
Testing
Date of receipt of test item ........................................... : 2009-06-24
Date(s) of performance of test...................................... : 2009-06-24 ~ 2009-07-08
General remarks
This report shall not be reproduced except in full without the written approval of the testing laboratory.
The test results presented in this report relate only to the item(s) tested.
Determination of the test result includes consideration of measurement uncertainty from the test equipment
and methods.
"(see appended table)" refers to a table appended to the report.
“(see remark #)” refers to a remark appended to the report.
“(see Annex #) refers to an annex appended to the report.
Throughout this report a point is used as the decimal separator.
General product information:
The equipment under testing (EUT) is a class II CD Micro with detachable power cord. The EUT includes two
unit: CD player and amplifier. The amplifier is supplied from the mains, The CD player is supplied from the
amplifier, it’s all SELV circuits.
The EUT is for indoors use only.
See test report SH09061297-002 for the standard IEC 60825-1:1993 + A1:1997 + A2:2001 and/or EN
60825-1:1994 + A1:2002 + A2:2001.
Model similarity:
Model MAS100 and Model MAS110 have the similar circuit schematic, components, critical components and
also the similar construction. The difference is the model name and functional terminal.
Model MAS100 has no DAB terminal.
Model MAS110 has DAB terminal.
Only the model MAS110 was tested and the test result is also available for model MAS100.
The equipment under testing (EUT) is a class II CD Micro with detachable power cord. The EUT includes two
unit: CD player and amplifier. The amplifier is supplied from the mains, The CD player is supplied from the
amplifier, it’s all SELV circuits.
The EUT is for indoors use only.
See test report SH09061297-002 for the standard IEC 60825-1:1993 + A1:1997 + A2:2001 and/or EN
60825-1:1994 + A1:2002 + A2:2001.
Model similarity:
Model MAS100 and Model MAS110 have the similar circuit schematic, components, critical components and
also the similar construction. The difference is the model name and functional terminal.
Model MAS100 has no DAB terminal.
Model MAS110 has DAB terminal.
Only the model MAS110 was tested and the test result is also available for model MAS100.