IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No: IEC/EN 60065H
TRF originator Intertek ETL SEMKO SH
14.3.1
Transformers and inductors marked with
manufacturer's name and type .............................. :
manufacturer's name and type .............................. :
Inductor: T1, T2, T3
Transformer: T4, T5
Dongguan City Dazhong
Electronic Co., Ltd.
T1, T2 type: SG08210
T3 type: SG08049
T4 type: SG08050
T5 type: SG08048
Transformer: T4, T5
Dongguan City Dazhong
Electronic Co., Ltd.
T1, T2 type: SG08210
T3 type: SG08049
T4 type: SG08050
T5 type: SG08048
Pass
Transformers and inductors separately approved . : No
N/A
14.3.2 General
Pass
14.3.3 Constructional
requirements
Pass
14.3.3.1
Clearances and creepage distances comply with
clause 13
clause 13
(See table 13.3& 13.4)
Pass
14.3.3.2
Transformers meet the constructional
requirements
requirements
Pass
14.3.4.1
Class II transformers have adequate separation
between hazardous live parts and accessible parts
(double or reinforced insulation)
between hazardous live parts and accessible parts
(double or reinforced insulation)
Pass
Coil formers and partition walls > 0,4 mm
Transformer bobbin thickness
at least 1.0mm.
at least 1.0mm.
Pass
14.3.4.2
Class I transformers, with basic insulation and
protective screening only if all 7 conditions of
14.3.4.2 are met
protective screening only if all 7 conditions of
14.3.4.2 are met
N/A
14.3.4.3
Separating transformers with at least basic
insulation
insulation
N/A
14.3.5.1
Class II transformers have adequate insulation
between hazardous live parts and accessible parts
(double or reinforced insulation)
between hazardous live parts and accessible parts
(double or reinforced insulation)
Pass
Coil formers and partition walls > 0,4 mm
Transformer bobbin thickness
at least 1.0mm.
at least 1.0mm.
Pass
14.3.5.2
Class I transformers have adequate insulation
between hazardous live parts and accessible
conductive parts or those conductive parts or
protective screens connected to a protective earth
terminal
between hazardous live parts and accessible
conductive parts or those conductive parts or
protective screens connected to a protective earth
terminal
N/A
Winding wires connected to protective earth have
adequate current-carrying capacity
adequate current-carrying capacity
N/A
14.4
High voltage components
No high-voltage component.
N/A
High-voltage components and assemblies:
U > 4 kV (peak) separately approved
U > 4 kV (peak) separately approved
N/A
Component meets category V-1 of IEC 60707
N/A