Page 8 of 89
Report No.: 17029429 001
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K
3
General requirements
P
Safety class of the apparatus ................................: Class II
P
4
General test conditions
P
4.1.4
Ventilation instructions require the use of the test
box
box
Not used
N/A
5
Marking and instructions
P
Comprehensible and easily discernible
The rating label is easily
discernible
discernible
P
Permanent durability against water and petroleum
spirit
spirit
Compliance was checked by
rubbing the marking by hand
for 15 s with cloth soaked with
water and cloth soaked with
petroleum spirit, it was not
possible to remove marking
plate and no curling observed
after the test
rubbing the marking by hand
for 15 s with cloth soaked with
water and cloth soaked with
petroleum spirit, it was not
possible to remove marking
plate and no curling observed
after the test
P
5.1
a) Identification, maker ........................................ : Identification mark:
P
b) Model number or type reference ....................... : HKTS200SUB
P
c) Class II symbol if applicable ............................. :
Marked on rear panel of
subwoofer
P
d) Nature of supply ............................................... : ~
P
e) Rated supply voltage ....................................... : 100-120V~ or 220-240V~,
indication on PCB for the set
voltage by CN2
voltage by CN2
P
f) Mains frequency if safety dependant ................. : 50/60Hz
P
g) Rated current or power consumption for
apparatus supplied by supply apparatus for general
use ..................................................................... :
apparatus supplied by supply apparatus for general
use ..................................................................... :
N/A
Measured current or power consumption ............. :
N/A
Deviation % (max 10%) ....................................... :
N/A
h) Rated current or power consumption for apparat-
us intended for connection to an a.c. mains supply :
us intended for connection to an a.c. mains supply :
200W
P
Measured current or power consumption ............. : (see appended table 7.1)
P
Measured current or power consumption for
Television set ...................................................... :
Television set ...................................................... :
N/A
Deviation % (max 10%) ....................................... : (see appended table 7.1)
P
5.2
a) Earth terminal
Class II apparatus
N/A
b) Hazardous live terminals
N/A