HKTS 200SUB (serv.man2) - Harman Kardon Audio EMC - CB Certificate (repair manual). Page 4

Read Harman Kardon HKTS 200SUB (serv.man2) EMC - CB Certificate online

 
 
 
 
Page 3 of 89 
 
 
 
Report No.17029429 0011 
 
TRF No. IEC60065K 
List of Attachments (including a total number of pages in each attachment):  
1. 
Photo documentation (15 pages) 
 
Summary of testing: 
Tests performed (name of test and test clause): 
1)  The Maximum ambient temperature is 45°C.  
2)  EUT is designed for altitudes up to and including 2000m above sea level. 
3)  Following tests performed during evaluation. 
Clause 
Test 
Durability of Marking Test 
5.1 
Input Current Test 
7.1  
Heating under Normal Operations 
7.2 
Vicat Softening Test 
8.3 
Hygroscopic Material Humidity Test (for wood enclosure) 
8.14 
50 N Test for Covers 
9.1.1.1 
Touch Current 
9.1.4 
Terminal Device Test 
9.1.6 
Plug Discharge Test 
9.1.7 
Resistance to External Forces (50 N) 
10.1 
Surge Test 
10.2 
Humidity Test 
10.3 
Insulation Resistance and Electric Strength 
11.1 
Touch Current under Fault Conditions 
11.2 
Heating under Fault Conditions 
12.1.1 
Bump Test 
12.1.2 
Vibration Test 
12.1.3 
Impact Test 
13.2 
Working Voltages 
13.3 & 13.4 
Clearance & Creepage Measurements 
17.1 
Torque Test 
19.1 
Test on a plane 
19.2 
100N force applied vertically downwards 
 
Testing location: 
See page 2. 