Read Harman Kardon HKTS 200SUB (serv.man2) EMC - CB Certificate online
Page 11 of 89
Report No.: 17029429 001
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K
Basic insulation bridged by components complying
with 14.3.4.3.
with 14.3.4.3.
No such components
N/A
Basic and supplementary insulation each being
bridged by a capacitor complying with 14.1 a)
bridged by a capacitor complying with 14.1 a)
No such capacitors
N/A
Double or reinforced insulation being bridged with 2
capacitors in series complying with 14.2.1 a)
capacitors in series complying with 14.2.1 a)
No such capacitors
N/A
Double or reinforced insulation being bridged with a
single capacitor complying with 14.2.1 b)
single capacitor complying with 14.2.1 b)
Approved Y1 capacitor bridged
between primary and
secondary circuits/metal
enclosure
between primary and
secondary circuits/metal
enclosure
(see appended table 14)
P
8.7
This clause is void
--
8.8
Basic or supplementary insulation > 0,4 mm (mm) :
Thickness of transformer
bobbin, see appended table 14
bobbin, see appended table 14
P
Reinforced insulation > 0,4 mm (mm) ...................:
See appended table 14 for
below information:
below information:
- thickness of enclosure
P
Thin sheet insulation (excluding non-separable thin
sheet insulation. See 8.22)
sheet insulation. See 8.22)
P
Basic or supplementary insulation, at least two
layers, each meeting 10.3
layers, each meeting 10.3
N/A
Basic or supplementary insulation, three layers any
two of which meet 10.3
two of which meet 10.3
N/A
Reinforced insulation, two layers each of which meet
10.3
10.3
N/A
Reinforced insulation, three layers any two which
meet 10.3
meet 10.3
(see appended table 10.3 and
clause 8.17)
clause 8.17)
P
8.9
Adequate insulation between internal hazardous live
conductors and accessible parts
conductors and accessible parts
Double/reinforced insulation
between primary live parts and
accessible parts
between primary live parts and
accessible parts
P
Adequate insulation between internal hazardous live
parts and conductors connected to accessible parts
parts and conductors connected to accessible parts
Basic insulated secondary
wires cannot touch hazardous
live parts, wire near to primary
side of power board already
fixed by ties.
wires cannot touch hazardous
live parts, wire near to primary
side of power board already
fixed by ties.
P
8.10
Double insulation between conductors connected to
the mains and accessible parts.
the mains and accessible parts.
P
Double insulation between internal hazardous live
parts and conductors connected to accessible parts.
parts and conductors connected to accessible parts.
P
8.11
Detaching of wires
P