Report No.: 17029429 001
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K
7.1.3
Temperature rise of parts acting as a support or as a
mechanical barrier
mechanical barrier
(see appended table 7.1)
P
7.1.4
Temperature rise of windings
(see appended table 7.1)
P
7.1.5
Parts not subject to a limit under 7.1.1 to 7.1.4
N/A
7.2
Softening temperature of insulating material
supporting parts conductively connected to the
mains carrying a current > 0,2 A at least 150
supporting parts conductively connected to the
mains carrying a current > 0,2 A at least 150
o
C
Bobbin of switching isolating
transformers TR1, TR2 and
TR3 made from phenolic
material and considered to be
sufficient in regard to the
temperature characteristic (150
transformers TR1, TR2 and
TR3 made from phenolic
material and considered to be
sufficient in regard to the
temperature characteristic (150
C). see appended table 7.2
only for bobbin of Line Filter
LF2.
LF2.
P
8
Constructional requirements with regard to the protection against electric
shock
shock
P
8.1
Conductive parts covered by lacquer, paper,
untreated textile oxide films and beads etc.
considered to be bare
untreated textile oxide films and beads etc.
considered to be bare
No such material
N/A
8.2
No shock hazard when changing voltage setting
device, fuse-links or handling drawers etc.
device, fuse-links or handling drawers etc.
It is not possible for user to
access fuse-link. No user or
service accessible voltage
setting device. No such
indicators or drawers
access fuse-link. No user or
service accessible voltage
setting device. No such
indicators or drawers
P
8.3
Insulation of hazardous live parts not provided by
hygroscopic material
hygroscopic material
168h, 40°C, RH 93% (for wood
material by client request)
material by client request)
P
8.4
No risk of electric shock from accessible parts or
from parts rendered accessible following the
removal of a cover which can be removed by hand
from parts rendered accessible following the
removal of a cover which can be removed by hand
No such cover which can be
removed by hand
removed by hand
N/A
8.5
Class I equipment
Class II apparatus
N/A
Basic insulation between hazardous live parts and
earthed accessible parts
earthed accessible parts
N/A
Resistors bridging basic insulation complying with
14.1 a)
14.1 a)
N/A
Capacitors bridging basic insulation complying with
14.2.1 a)
14.2.1 a)
N/A
Protective earthing terminal
N/A
8.6
Class II equipment and Class II constructions within
Class I equipment
Class I equipment
Class II equipment
P
Double or reinforced insulation between hazardous
live parts and accessible parts
live parts and accessible parts
Reinforced or double insulation
used between hazardous live
parts and accessible parts
used between hazardous live
parts and accessible parts
P
Components bridging double or reinforced insulation
complying with 14.1 a) or 14.3
complying with 14.1 a) or 14.3
Switching isolating transformer
complied with clause 14.3
complied with clause 14.3
P