Read Harman Kardon HKTS 200SUB (serv.man2) EMC - CB Certificate online
Page 7 of 89
Report No.17029429 0011
TRF No. IEC60065K
General product information:
1.
The EUT covered by this report is subwoofer with amplifier.
2.
The manufacturer specified maximum ambient temperature is 45
C. EUT operated with altitude up to
2000m above sea level. Overvoltage category II is assumed during evaluation
3.
The same power board is used for 100-120V~ and 220-240V~ rating, except component VR1 only
mounted on power board for 100-120V input only. Both types of power board will be manufactured by
short-circuit connector CN2 via jumper to have the power board operate at 100-120V~ or open-circuit
connector CN2 in order to operate the power board at 220-240V~.
The product mainly consists of:
-
Built-in power board.
-
Amplifier/Control board.
-
Speaker