Report No.: 17029429 001
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K
No undue reduction of creepages or clearance
distances if wires become detached
distances if wires become detached
Primary wires connected to
power board by connector.
Secondary wires from power
board & other wires connected
to secondary PCB by
pluggable wire connector or
hooked-in soldering or
soldering and additionally
fixed by glue.
power board by connector.
Secondary wires from power
board & other wires connected
to secondary PCB by
pluggable wire connector or
hooked-in soldering or
soldering and additionally
fixed by glue.
P
Vibration test carried out ......................................:
Yes
P
8.12
This clause is void
—
8.13
Adequate fastening of windows, lenses, lamp covers
etc. (pull test 20 N for 10 s)
etc. (pull test 20 N for 10 s)
No such parts
N/A
8.14
Adequate fastening of covers (push/pull test 50 N for
10 s)
10 s)
P
8.15
No risk of damage to the insulation of internal wiring
due to hot parts or sharp edges
due to hot parts or sharp edges
Internal wires can not touch
hot parts or sharp edges
which can damage its
insulation
hot parts or sharp edges
which can damage its
insulation
P
8.16
Only special supply equipment can be used
N/A
8.17
Insulated winding wire without additional interleaved
insulation
insulation
Triple insulated wire used on
transformer TR3
transformer TR3
P
8.18
Endurance test as required by 8.17
N/A
8.19
Disconnection from the mains
P
8.19.1
Disconnect device
Type: mains plug on non-
detachable power cord
detachable power cord
P
All-pole switch or circuit breaker with >3mm contact
separation
separation
No such switch
N/A
8.19.2
Mains switch ON indication
N/A
8.20
Switch not fitted in the mains cord
Mains switch located on rear
enclosure
enclosure
N/A
8.21
Bridging components comply with clause 14
No such components used
N/A
8.22
Non-separable thin sheet material
N/A
9
Electric shock hazard under normal operating conditions
P
9.1
Testing on the outside
P
9.1.1
For voltages >1000 V ac or >1500 V dc complies
with clause 13.3.1 for basic insulation
with clause 13.3.1 for basic insulation
< 1000 V
N/A
9.1.1.1
a) Open circuit voltages
(see appended table 9.1.1)
P
b) Touch current measured from terminal devices
using the network in annex D ...............................:
using the network in annex D ...............................:
(see appended table 9.1.1)
P
c) Discharge not exceeding 45
μC
Discharge not exceeding
45
45
μC
P