Report Ref No.: 615320 
IEC 60065 
Clause 
Requirement + Test 
 
Result - Remark 
Verdict
 
6 HAZARDOUS 
RADIATION 
 
6.1 
Ionizing radiation < 36 pA/kg (0,5 mR/h) 
 
N/A 
6.2 
Laser radiation, emission limits to IEC 60825-1 ..  
N/A 
 
Emission limits under fault conditions  .............. :  
N/A 
 
 
HEATING UNDER NORMAL OPERATING CONDITIONS 
 
7.1 
Temperature rises not exceeding specified 
values, any single protective device defeated 
except those of Cl. 7.1 a) and b) 
 P 
7.1.1 
Temperature rise of accessible parts 
 
7.1.2 
Temperature rise of parts providing electrical 
insulation 
 P 
7.1.3 
Temperature rise of parts acting as a support or 
as a mechanical barrier 
 P 
7.1.4 
Temperature rise of windings 
 
7.1.5 
Parts not subject to a limit under 7.1.1 to 7.1.4 
 
7.2 
Softening temperature of insulating material 
supporting parts conductively connected to the 
mains carrying a current > 0,2 A at least 150
 o
Mains fuse holder 
 
 
CONSTRUCTIONAL REQUIREMENTS WITH REGARD TO THE PROTECTION 
AGAINST ELECTRIC SHOCK 
 
8.1 
Conductive parts covered by lacquer, paper, 
untreated textile oxide films and beads etc. 
considered to be bare 
PCB P 
8.2 
No shock hazard when changing voltage 
setting device, fuse-links or handling drawers 
etc. 
Tools are required 
N/A 
8.3 
Insulation of hazardous live parts not provided 
by hygroscopic material 
No hygroscopic material 
8.4 
No risk of electric shock following the removal 
of a cover which can be removed by hand 
 P 
8.5 
Class I equipment 
 
 
 
Basic insulation between hazardous live parts 
and earthed accessible parts 
 N/A 
 
Capacitors bridging basic insulation complying 
with 14.2.1 a) 
 N/A 