Read Harman Kardon HK 3770 (serv.man2) EMC - CB Certificate online
Page 13 of 51
Report No 248607.
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K
9
Electric shock hazard under normal operating conditions
9.1
Testing on the outside
P
9.1.1
For voltages >1000 V ac or >1500 V dc complies
with clause 13.3.1 for basic insulation
with clause 13.3.1 for basic insulation
No voltage >1000 V ac or
>1500 V dc
>1500 V dc
N/A
9.1.1.1
a) Open circuit voltages
Mains input voltage
>35 V ac, see below.
>35 V ac, see below.
—
b) Touch current measured from terminal devices
using the network in annex D ................................ :
using the network in annex D ................................ :
U1: Max. 0.68 V (peak)
U2: Max. 0.31 V (peak)
(Tested at 264 V/ 60 Hz)
U2: Max. 0.31 V (peak)
(Tested at 264 V/ 60 Hz)
P
c) Discharge not exceeding 45 μC
No part or contact of a
terminal with stored voltages
between 60 V – 150 kV.
terminal with stored voltages
between 60 V – 150 kV.
N/A
d) Energy of discharge not exceeding 350 mJ
No part or contact of a terminal
with stored voltages exceeding
15 kV.
with stored voltages exceeding
15 kV.
N/A
9.1.1.2
Test with test finger and test probe
No access to hazardous
live parts.
live parts.
P
9.1.2
No hazardous live shafts of knobs, handles or levers No live shafts of knobs,
handles or levers.
N/A
9.1.3
Ventilation holes and other holes tested by means of
4 mm x 100 mm test pin
4 mm x 100 mm test pin
No access for the test pin.
P
9.1.4
Terminal devices tested with 1 mm x 20 mm test pin
(10 N); test probe D of IEC 61032
(10 N); test probe D of IEC 61032
Does not reach hazardous
live parts.
live parts.
P
Terminal devices tested with 1 mm x 100 mm
straight wire (1 N); test probe D of IEC 61032
straight wire (1 N); test probe D of IEC 61032
Does not reach hazardous
live parts.
live parts.
P
9.1.5
Pre-set controls tested with 2.5 mm x 100 mm test
pin (10 N); test probe C of IEC 61032
pin (10 N); test probe C of IEC 61032
No pre-set controls.
N/A
9.1.6
No shock hazard due to stored charge on withdrawal
of the mains plug; voltage (V) after 2 s .................. :
of the mains plug; voltage (V) after 2 s .................. :
32 V dc after 2 s,
Bleeder resistor provided.
See clause 14.1 b), and
appended table, list of critical
components.
Bleeder resistor provided.
See clause 14.1 b), and
appended table, list of critical
components.
P
If C is not greater than 0,1 μF no test needed
>0,1 μF
N/A
9.1.7
Resistance to external forces
P
a) Test probe 11 of IEC 61032 for 10 s (50 N)
Test with test finger results
in no hazard.
in no hazard.
P
b) Test hook of fig. 4 for 10 s (20 N)
Test with test hook results
in no hazard.
in no hazard.
P
c) 30 mm diameter test tool for 5 s (100 or 250 N)
Tested 100 N result in no
hazard.
hazard.
P
9.2
No hazard after removing a cover by hand
No cover removable by hand
N/A
Click on the first or last page to see other HK 3770 (serv.man2) service manuals if exist.