Read Harman Kardon HK 3770 (serv.man2) EMC - CB Certificate online
Page 8 of 51
Report No 248607.
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K
3 General
requirements
Safety class of the apparatus .................................. :
Class II apparatus.
P
4
General test conditions
4.1.4
Ventilation instructions require the use of the test
box
box
Tested in a wooden test box
according to instructions in
user manual.
(Tested box condition: 30 cm
for top and other sides)
according to instructions in
user manual.
(Tested box condition: 30 cm
for top and other sides)
P
5
Marking and instructions
Comprehensible and easily discernible
On front and rear side of the
enclosure,
enclosure,
P
Permanent durability against water and petroleum
spirit
spirit
Tested with water / petroleum
sprit.
sprit.
P
5.1 a)
Identification,
maker ............................................ : Trade mark:
P
b) Model number or type reference ......................... : Model no.
HK3770/230
P
c) Class II symbol if applicable ................................ : Class II symbol according to
IEC 60417-5172 is applied.
P
d) Nature of supply ................................................... : a.c. symbol according to
IEC 60417-5032.is applied.
P
e) Rated supply voltage .......................................... : 220-240 V~
P
f) Mains frequency if safety dependant ................... : 50/60 Hz
P
g) Rated current or power consumption for
apparatus supplied by supply apparatus for general
use ........................................................................... :
apparatus supplied by supply apparatus for general
use ........................................................................... :
The apparatus is connection
to an a.c. mains supply.
to an a.c. mains supply.
N/A
Measured current or power consumption ............... :
N/A
Deviation % (max 10%) ........................................... :
N/A
h) Rated current or power consumption for apparat-
us intended for connection to an a.c. mains supply :
us intended for connection to an a.c. mains supply :
300 W
P
Measured current or power consumption ............... : Max. 272.8 W
(see appended table 7.1)
P
Measured current or power consumption for
Television set ........................................................... :
Television set ........................................................... :
No television set.
N/A
Deviation % (max 10%) ........................................... : Not exceed the marked value.
P
5.2
a) Earth terminal
Class II apparatus.
N/A