Read Harman Kardon HK 3770 (serv.man2) EMC - CB Certificate online
Page 12 of 51
Report No 248607.
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K
8.9
Adequate insulation between internal hazardous live
conductors and accessible parts
conductors and accessible parts
Double insulated.
P
Adequate insulation between internal hazardous live
parts and conductors connected to accessible parts
parts and conductors connected to accessible parts
Single insulated, but safety
anchored.
anchored.
P
8.10
Double insulation between conductors connected to
the mains and accessible parts.
the mains and accessible parts.
Double insulated according to
8.9 and 10.3
8.9 and 10.3
P
Double insulation between internal hazardous live
parts and conductors connected to accessible parts.
parts and conductors connected to accessible parts.
Single insulated, but safety
anchored.
anchored.
N/A
8.11
Detaching of wires
P
No undue reduction of creepages or clearance
distances if wires become detached
distances if wires become detached
Inlet connected wires
hooked-in before soldered.
Other primary wires connected
with multi-contact housing.
hooked-in before soldered.
Other primary wires connected
with multi-contact housing.
P
Vibration test carried out ........................................ :
See clause 12.1.2
—
8.12
This clause is void
—
8.13
Adequate fastening of windows, lenses, lamp covers
etc. (pull test 20 N for 10 s)
etc. (pull test 20 N for 10 s)
Adequately fastened.
P
8.14
Adequate fastening of covers (push/pull test 50 N for
10 s)
10 s)
Covers adequately fastened
with screws.
with screws.
P
8.15
No risk of damage to the insulation of internal wiring
due to hot parts or sharp edges
due to hot parts or sharp edges
Wires safety anchored away
from parts with high
temperature.
from parts with high
temperature.
P
8.16
Only special supply equipment can be used
Not supplied by a special
supply apparatus.
supply apparatus.
N/A
8.17
Insulated winding wire without additional interleaved
insulation
insulation
No such winding wire
N/A
8.18
Endurance test as required by 8.17
No such insulation winding is
used.
used.
N/A
8.19
Disconnection from the mains
See below
P
8.19.1
Disconnect device
Appliance coupler is used as
disconnect devices.
disconnect devices.
P
All-pole switch or circuit breaker with >3mm contact
separation
separation
No all-pole switch or circuit
breaker.
breaker.
N/A
8.19.2
Mains switch ON indication
No mains switch, however
LED for ON indication
provided.
LED for ON indication
provided.
P
8.20
Switch not fitted in the mains cord
No switch in the mains cord.
P
8.21
Bridging components comply with clause 14
No such components.
N/A
8.22
Non-separable thin sheet material
No non-separable thin sheet
material.
material.
N/A