HK 3770 (serv.man2) - Harman Kardon Audio EMC - CB Certificate (repair manual). Page 13

Read Harman Kardon HK 3770 (serv.man2) EMC - CB Certificate online

  
Page 9 of 51
Report No 248607.
 
  
 
 
 
 
 
IEC 60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict
 
TRF No. IEC60065K 
 
 
b) Hazardous live terminals  
No hazardous live terminals. 
The output signal will rise to 
48.1 Vp at maximum output 
power, and 17 Vp at 1/8 output 
power (normal), if the speaker 
load is disconnected in the 
speaker terminal. 
No hazard. 
P 
 
c) Markings on supply output terminals 
No socket outlet for providing 
power to other apparatus 
except USB terminal. 
“5V/2.1A 
”marked for 
USB output terminal. 
P 
5.3 
a) Use of triangle with exclamation mark  
Correct symbol applied: 
- In rear side in connection 
  with CAUTION of opening 
- In circuit diagram 
further, no incorrect use of 
this symbol is found. 
P 
 
b) marking on loudspeaker grille, IEC 60417-5036 
Not used loudspeaker grille 
N/A 
5.4 
Instructions for use 
User information in the 
following language: English 
See comments in Summary 
of Testing. 
P 
5.4.1 
 
a) Mains powered equipment not exposed to 
dripping or splashing. Warning concerning objects 
filled with liquid, etc.  
The user manual includes 
information about danger 
concerning dripping or 
adequate instructions supplied 
splashing and objects filled 
with liquids. 
P 
 
b) Hazardous live terminals, instructions for wiring    No hazardous live terminals. 
N/A 
 
c) Instructions for replacing lithium battery  
No battery 
N/A 
 
d) Class I earth connection warning  
Class II apparatus. 
N/A 
 
e) Instructions for multimedia system connection  
Instructions for multimedia 
system connection provided 
In user manual. 
P 
 
f) Special stability warning for attachment of the 
apparatus to the floor/wall  
No such equipment 
N/A 
 
g) Warning: battery exposure to heat  
No such equipment 
N/A 
 
h) Warning: protective film on CRT face  
No CRT 
N/A 
5.4.2 
a-b) Disconnect device: plug/coupler or all-pole 
mains switch location, accessibility and markings  
Appliance coupler is 
disconnecting device and 
readily operable. 
P 
 
c) Instructions for permanently connected equipment  Not permanently connected 
equipment. 
N/A 
 
Marking, signal lamps or similar for completely 
disconnection from the mains  
Information provided in user 
manual. 
P 
 
Page of 93