IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K
Class I protective earthing maintained
Class II apparatus
N/A
11.2.7
Temperature rise of parts not subject to the limits of
11.2.1 to 11.2.6 shall not exceed the limits in table 3,
item e), "Fault conditions".
11.2.1 to 11.2.6 shall not exceed the limits in table 3,
item e), "Fault conditions".
(see appended table 11.2)
P
12 Mechanical
strength
12.1.1
Bump test where mass >7 kg
Mass: 5.0 kg
N/A
12.1.2
Vibration test
Assessed to be
satisfactory constructed.
satisfactory constructed.
P
12.1.3
Impact hammer test
No damage in the sense of
this standard.
this standard.
P
Steel ball test
No damage in the sense of
this standard.
this standard.
P
12.1.4
Drop test for portable apparatus where mass ≤ 7 kg No portable apparatus.
N/A
12.1.5
Thermoplastic enclosures stress relief test
No risk of shrinkage or
distortion on enclosure.
distortion on enclosure.
P
12.2
Fixing of knobs, push buttons, keys and levers
Normal use will not impair
the protection against
electric shock.
the protection against
electric shock.
P
12.3
Remote controls with hazardous live parts
No remote control containing
hazardous live parts.
hazardous live parts.
N/A
12.4
Drawers (pull test 50 N, 10 s)
No drawers
N/A
12.5
Antenna coaxial sockets providing isolation
No such antenna coaxial
sockets.
sockets.
N/A
12.6
Telescoping or rod antennas construction
No telescoping or rod
antennas.
antennas.
N/A
12.6.1
Telescoping or rod antennas securement
N/A
13
Clearances and creepage distances
13.1
Clearances in accordance with 13.3
See 13.3
P
Creepage distances in accordance with 13.4
See 13.4
P
13.2
Determination of working voltage
Conventional transformer
used. Upper rated supply
voltage. (240 V) applied in
determining the working
voltage
used. Upper rated supply
voltage. (240 V) applied in
determining the working
voltage
P
13.3
Clearances
2 N for internal parts and 30 N
for enclosure are considered
when determining clearances.
for enclosure are considered
when determining clearances.
P
13.3.1 General
Considered.
P
13.3.2
Circuits conductively connected to the mains comply
with table 8 and, where applicable, table 9 ............ :
with table 8 and, where applicable, table 9 ............ :
(see appended table 13)
P
13.3.3
Circuits not conductively connected to the mains
comply with table 10
comply with table 10
No hazardous secondary
voltages.
voltages.
N/A