GO PLAY MICRO (serv.man4) - Harman Kardon Audio EMC - CB Certificate (repair manual). Page 15

Read Harman Kardon GO PLAY MICRO (serv.man4) EMC - CB Certificate online

 
 
 
 
Page 15 of 70 
Report No.: JGZ0512196-3 
IEC 60950-1 
Clause 
Requirement – Test   
Result – Remark   
Verdict 
 
  
TRF 
No.:IEC60950_1A 
Intertek Testing Services Shenzhen Ltd. Guangzhou GDD Branch
 
3/F., Hengyun Building, 728 Kaifa Ave., Guangzhou Economic & Technological Development District, Guangzhou, China 
Tel: (86 20) 8396 6868    Fax: (86 20) 8222 8170 Website: www.china.intertek-etlsemko.com 
 
3.2.8 Cord 
guards 
 
N/A 
 
D (mm); test mass (g)  ....................................... :   
⎯ 
 
Radius of curvature of cord (mm)....................... :   
⎯ 
3.2.9 
Supply wiring space 
 
N/A 
 
3.3 
Wiring terminals for connection of external conductors 
N/A 
3.3.1 Wiring 
terminals 
No wiring terminal 
N/A 
3.3.2 
Connection of non-detachable power supply 
cords 
 
N/A 
3.3.3 Screw 
terminals 
 
N/A 
3.3.4 
Conductor sizes to be connected 
 
N/A 
 
Rated current (A), cord/cable type, cross-
sectional area (mm
2
) .......................................... : 
 
⎯ 
3.3.5 
Wiring terminal sizes 
 
N/A 
 
Rated current (A), type and nominal thread 
diameter (mm) .................................................. : 
 
⎯ 
3.3.6 
Wiring terminals design 
 
N/A 
3.3.7 
Grouping of wiring terminals 
 
N/A 
3.3.8 Stranded 
wire 
 
N/A 
 
3.4 
Disconnection from the mains supply 
3.4.1 General 
requirement 
 P 
3.4.2 Disconnect 
devices 
Appliance inlet as part of the 
equipment is considered as the 
disconnect device 
3.4.3 
Permanently connected equipment 
The EUT is not such equipment 
N/A 
3.4.4 
Parts which remain energized 
 N/A 
3.4.5 
Switches in flexible cords 
 N/A 
3.4.6 
Single-phase equipment and d.c. equipment 
Appliance inlet of equipment is 
provided 
3.4.7 Three-phase 
equipment 
 N/A 
3.4.8 Switches 
as disconnect devices 
 N/A 
3.4.9 
Plugs as disconnect devices 
 N/A 
3.4.10 Interconnected 
equipment 
 N/A 
Page of 81