Read Harman Kardon GO PLAY MICRO (serv.man4) EMC - CB Certificate online
Page 14 of 70
Report No.: JGZ0512196-3
IEC 60950-1
Clause
Requirement – Test
Result – Remark
Verdict
TRF
No.:IEC60950_1A
Intertek Testing Services Shenzhen Ltd. Guangzhou GDD Branch
3/F., Hengyun Building, 728 Kaifa Ave., Guangzhou Economic & Technological Development District, Guangzhou, China
Tel: (86 20) 8396 6868 Fax: (86 20) 8222 8170 Website: www.china.intertek-etlsemko.com
3
WIRING, CONNECTIONS AND SUPPLY
P
3.1 General
P
3.1.1
Current rating and overcurrent protection
(see appended table 1.5.1)
P
3.1.2
Protection against mechanical damage
P
3.1.3
Securing of internal wiring
P
3.1.4
Insulation of conductors
(see appended table 5.2)
P
3.1.5
Beads and ceramic insulators
N/A
3.1.6
Screws for electrical contact pressure
No screws are used as
electrical connections
electrical connections
N/A
3.1.7
Insulating materials in electrical connections
N/A
3.1.8
Self-tapping and spaced thread screws
No such screws are used
N/A
3.1.9
Termination of conductors
The internal wires are hooked
and soldered.
and soldered.
P
10 N pull test
P
3.1.10
Sleeving on wiring
No such sleeving are used
N/A
3.2
Connection to an a.c. mains supply or a d.c. mains supply
P
3.2.1 Means
of connection ......................................... : Appliance inlet used
P
3.2.1.1
Connection to an a.c. mains supply
P
3.2.1.2
Connection to a d.c. mains supply
N/A
3.2.2
Multiple supply connections
There is only one supply
connection for the EUT
connection for the EUT
N/A
3.2.3
Permanently connected equipment
The EUT is not such type
N/A
Number of conductors, diameter (mm) of cable
and conduits ..................................................... :
and conduits ..................................................... :
⎯
3.2.4 Appliance
inlets
P
3.2.5
Power supply cords
N/A
3.2.5.1
AC power supply cords
N/A
Type.................................................................... :
⎯
Rated current (A), cross-sectional area (mm
2
),
AWG ................................................................... :
⎯
3.2.5.2
DC power supply cords
N/A
3.2.6
Cord anchorages and strain relief
N/A
Mass of equipment (kg), pull (N) ..................... :
⎯
Longitudinal
displacement (mm) ....................... :
⎯
3.2.7
Protection against mechanical damage
N/A
Click on the first or last page to see other GO PLAY MICRO (serv.man4) service manuals if exist.