GO PLAY MICRO (serv.man4) - Harman Kardon Audio EMC - CB Certificate (repair manual). Page 10

Read Harman Kardon GO PLAY MICRO (serv.man4) EMC - CB Certificate online

 
 
 
 
Page 10 of 70 
Report No.: JGZ0512196-3 
IEC 60950-1 
Clause 
Requirement – Test   
Result – Remark   
Verdict 
 
  
TRF 
No.:IEC60950_1A 
Intertek Testing Services Shenzhen Ltd. Guangzhou GDD Branch
 
3/F., Hengyun Building, 728 Kaifa Ave., Guangzhou Economic & Technological Development District, Guangzhou, China 
Tel: (86 20) 8396 6868    Fax: (86 20) 8222 8170 Website: www.china.intertek-etlsemko.com 
 
 
Regulating network limited output under normal 
operating conditions and overcurrent protective 
device limited output under single fault condition 
 
N/A 
 
Output voltage (V), output current (A), apparent 
power (VA)......................................................... : 
See the Note below 
⎯ 
 
Current rating of overcurrent protective device (A)  
⎯ 
Note: 
The output of the power supply complies with the requirement of inherently Limited Power Source. 
Limits: Isc 
≤ 8.0 A, VA ≤ 100 VA. 
Measured Uoc = 25.6 Vdc, Isc = 3.70 A, VA = 86.3 VA, under max. overload at output (the worst case). 
Limits: Isc 
≤ 8.0 A, VA ≤ 100 VA. 
Measured Uoc = 25.6 Vdc, Isc = 3.57 A, VA = 80 VA, under short R10. 
Limits: Isc 
≤ 8.0 A, VA ≤ 100 VA. 
Measured Uoc = 25.6 Vdc, Isc = 3.60 A, VA = 81 VA, under short D1. 
Limits: Isc 
≤ 8.0 A, VA ≤ 100 VA. 
Measured Uoc = 25.6 Vdc, Isc = 3.70 A, VA = 85.8 VA, under short R24. 
Limits: Isc 
≤ 8.0 A, VA ≤ 100 VA. 
Measured Uoc = 25.6 Vdc, Isc = 3.70 A, VA = 85.5 VA, under short R16. 
 
2.6 
Provisions for earthing and bonding 
N/A 
2.6.1 Protective 
earthing 
Class II equipment 
N/A 
2.6.2 Functional 
earthing 
 
N/A 
2.6.3 
Protective earthing and protective bonding 
conductors 
 
N/A 
2.6.3.1 General 
 
N/A 
2.6.3.2 
Size of protective earthing conductors 
 
N/A 
 
Rated current (A), cross-sectional area (mm
2
), 
AWG ................................................................... : 
 
⎯ 
2.6.3.3 
Size of protective bonding conductors 
 
N/A 
 
Rated current (A), cross-sectional area (mm
2
), 
AWG ................................................................... : 
 
⎯ 
2.6.3.4 
Resistance (
Ω) of earthing conductors and their 
terminations, test current (A) .............................. : 
 
N/A 
2.6.3.5 Colour 
of insulation............................................. :   
N/A 
2.6.4 Terminals 
 
N/A 
2.6.4.1 General 
 
N/A 
2.6.4.2 
Protective earthing and bonding terminals 
 
N/A 
Page of 81
Display