Read Harman Kardon GO PLAY MICRO (serv.man4) EMC - CB Certificate online
Page 12 of 70
Report No.: JGZ0512196-3
IEC 60950-1
Clause
Requirement – Test
Result – Remark
Verdict
TRF
No.:IEC60950_1A
Intertek Testing Services Shenzhen Ltd. Guangzhou GDD Branch
3/F., Hengyun Building, 728 Kaifa Ave., Guangzhou Economic & Technological Development District, Guangzhou, China
Tel: (86 20) 8396 6868 Fax: (86 20) 8222 8170 Website: www.china.intertek-etlsemko.com
2.8.7
Switches and relays
N/A
2.8.7.1 Contact
gaps (mm) ........................................... :
N/A
2.8.7.2 Overload
test
N/A
2.8.7.3 Endurance
test
N/A
2.8.7.4
Electric strength test
N/A
2.8.8 Mechanical
actuators
N/A
2.9 Electrical
insulation
P
2.9.1
Properties of insulating materials
Natural rubber, hygroscopic
materials or asbestos are not
used
materials or asbestos are not
used
P
2.9.2 Humidity
conditioning
See remark below
P
Humidity (%) ..................................................... : 93
⎯
Temperature (
°C) .............................................. : 30
⎯
2.9.3
Grade of insulation
Considered
P
2.10
Clearances, creepage distances and distances through insulation
P
2.10.1 General
P
2.10.2
Determination of working voltage
P
2.10.3 Clearances
P
2.10.3.1 General
P
2.10.3.2
Clearances in primary circuit
(see appended table 2.10.3 and
2.10.4)
2.10.4)
P
2.10.3.3
Clearances in secondary circuits
N/A
2.10.3.4
Measurement of transient voltage levels
N/A
2.10.4 Creepage
distances
(see appended table 2.10.3 and
2.10.4)
2.10.4)
P
CTI
tests.............................................................. :
Considered as Material Group
IIIb
IIIb
⎯
2.10.5 Solid
insulation
P
2.10.5.1
Minimum distance through insulation
(see appended table 2.10.5)
P
2.10.5.2
Thin sheet material
P
Number of layers (pcs)........................................ :
⎯
Electric strength test
(see appended table 5.2)
⎯
2.10.5.3 Printed
boards
N/A
Distance through insulation
N/A
Electric strength test for thin sheet insulating
material
material
⎯