GO PLAY MICRO (serv.man2) - Harman Kardon Audio EMC - CB Certificate (repair manual). Page 13

Read Harman Kardon GO PLAY MICRO (serv.man2) EMC - CB Certificate online

 
Page 12 of 58 
Report No. 15039146 001 
 
 
 
IEC 60950-1 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
 
TRF No. IEC60950_1B 
 
 
 
c) Regulating network limited output under normal 
operating and single fault condition 
 
N/A 
 
d) Overcurrent protective device limited output 
 
N/A 
 
Max. output voltage (V), max. output current (A), 
max. apparent power (VA)......................................: 
 
 
 
Current rating of overcurrent protective device (A) .:   
 
 
Use of integrated circuit (IC) current limiters 
(See Annex CC) 
 
 
2.6 
Provisions for earthing and bonding 
N/A 
2.6.1 
Protective earthing 
 
N/A 
2.6.2 
Functional earthing 
 
N/A 
2.6.3 
Protective earthing and protective bonding 
conductors 
 
N/A 
2.6.3.1 
General 
 
N/A 
2.6.3.2 
Size of protective earthing conductors 
 
N/A 
 
Rated current (A), cross-sectional area (mm
2
), 
AWG .......................................................................: 
 
 
2.6.3.3 
Size of protective bonding conductors 
 
N/A 
 
Rated current (A), cross-sectional area (mm
2
), 
AWG .......................................................................: 
 
 
 
Protective current rating (A), cross-sectional area 
(mm
2
), AWG ...........................................................: 
 
N/A 
2.6.3.4 
Resistance of earthing conductors and their 
terminations; resistance (
), voltage drop (V), test 
current (A), duration (min) ......................................: 
 
N/A 
2.6.3.5 
Colour of insulation .................................................: 
 
N/A 
2.6.4 
Terminals 
 
N/A 
2.6.4.1 
General 
 
N/A 
2.6.4.2 
Protective earthing and bonding terminals 
 
N/A 
 
Rated current (A), type, nominal thread diameter 
(mm) .......................................................................: 
 
 
2.6.4.3 
Separation of the protective earthing conductor 
from protective bonding conductors 
 
N/A 
2.6.5 
Integrity of protective earthing 
 
N/A 
2.6.5.1 
Interconnection of equipment 
 
N/A 
2.6.5.2 
Components in protective earthing conductors and 
protective bonding conductors 
 
N/A 
2.6.5.3 
Disconnection of protective earth 
 
N/A 
2.6.5.4 
Parts that can be removed by an operator 
 
N/A 
2.6.5.5 
Parts removed during servicing 
 
N/A 
Page of 70