Read Harman Kardon GO PLAY MICRO (serv.man2) EMC - CB Certificate online
Page 10 of 58
Report No. 15039146 001
IEC 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60950_1B
2.1
Protection from electric shock and energy hazards
P
2.1.1
Protection in operator access areas
Only SELV inside the unit. No
electrical shock or energy
hazards.
electrical shock or energy
hazards.
P
2.1.1.1
Access to energized parts
Compliance of protection
against contact with
hazardous energized parts
checked:
against contact with
hazardous energized parts
checked:
P
Test by inspection .................................................:
Complied.
P
Test with test finger (Figure 2A) ...........................:
P
Test with test pin (Figure 2B) ................................:
N/A
Test with test probe (Figure 2C) ...........................:
N/A
2.1.1.2
Battery compartments
No TNV circuits.
N/A
2.1.1.3
Access to ELV wiring
N/A
Working voltage (Vpeak or Vrms); minimum
distance through insulation (mm)
distance through insulation (mm)
(see appended tables 2.10.2
and 2.10.5)
and 2.10.5)
2.1.1.4
Access to hazardous voltage circuit wiring
N/A
2.1.1.5
Energy hazards ......................................................: No energy hazard in operator
access area.
P
2.1.1.6
Manual controls
N/A
2.1.1.7
Discharge of capacitors in equipment
N/A
Measured voltage (V); time-constant (s) ................:
2.1.1.8
Energy hazards – d.c. mains supply
N/A
a) Capacitor connected to the d.c. mains supply ...:
N/A
b) Internal battery connected to the d.c. mains
supply .....................................................................:
supply .....................................................................:
N/A
2.1.1.9
Audio amplifiers .....................................................: No parts of audio amplifier are
accessible for the users.
P
2.1.2
Protection in service access areas
N/A
2.1.3
Protection in restricted access locations
The unit not intended to be
used in restricted locations.
used in restricted locations.
N/A
2.2
SELV circuits
Supply from power adaptor that is considered to carry SELV at below 240VA only. No
risk of electrical shock or energy hazards.
Supply from power adaptor that is considered to carry SELV at below 240VA only. No
risk of electrical shock or energy hazards.
P
2.2.1
General requirements
See below.
P
2.2.2
Voltages under normal conditions (V) ...................:
42.4V peak or 60V d.c. are
not exceeded in SELV circuit
under normal operation.
not exceeded in SELV circuit
under normal operation.
See appended table 2.2.2.
P