Read Harman Kardon GO PLAY MICRO (serv.man2) EMC - CB Certificate online
Page 8 of 58
Report No. 15039146 001
IEC 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60950_1B
1.6.2
Input current
(see appended table 1.6.2)
P
1.6.3
Voltage limit of hand-held equipment
Not hand-held equipment.
N/A
1.6.4
Neutral conductor
N/A
1.7
Marking and instructions
P
1.7.1
Power rating and identification markings
See below.
P
1.7.1.1
Power rating marking
See below
P
Multiple mains supply connections..........................: Not directly connected to the
mains.
N/A
Rated voltage(s) or voltage range(s) (V) ...............: 24V
P
Symbol for nature of supply, for d.c. only ...............: IEC 60417-5031 used.
See above.
P
Rated frequency or rated frequency range (Hz) ....: DC source.
N/A
Rated current (mA or A) ........................................: 2.3A
P
1.7.1.2
Identification markings
See below.
P
Manufacturer’s name or trade-mark or identification
mark .......................................................................:
mark .......................................................................:
P
Model identification or type reference ....................: Go + Play micro
P
Symbol for Class II equipment only .......................: Class III equipment.
N/A
Other markings and symbols .................................: Other markings and symbols
do not give rise to
misunderstanding.
misunderstanding.
P
1.7.2
Safety instructions and marking
Provided with marking
regarding use of specified
power supply, refer to copy of
marking plate.
regarding use of specified
power supply, refer to copy of
marking plate.
P
1.7.2.1
General
Instructions are available.
P
1.7.2.2
Disconnect devices
Not directly connected to the
mains.
mains.
N/A
1.7.2.3
Overcurrent protective device
Not directly connected to the
mains.
mains.
N/A
1.7.2.4
IT power distribution systems
Not directly connected to the
mains.
mains.
N/A
1.7.2.5
Operator access with a tool
N/A
1.2.7.6
Ozone
N/A
1.7.3
Short duty cycles
Equipment is designed for
continuous operation.
continuous operation.
N/A
1.7.4
Supply voltage adjustment ....................................:
No supply voltage adjustment.
N/A
Click on the first or last page to see other GO PLAY MICRO (serv.man2) service manuals if exist.