Report No. 15039146 001 
 
 
 
IEC 60950-1 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
 
TRF No. IEC60950_1B 
 
 
1.6.2 
Input current 
(see appended table 1.6.2)  
1.6.3 
Voltage limit of hand-held equipment 
Not hand-held equipment. 
N/A 
1.6.4 
Neutral conductor  
 
N/A 
 
1.7 
Marking and instructions 
1.7.1 
Power rating and identification markings 
See below. 
1.7.1.1 
Power rating marking 
See below 
 
Multiple mains supply connections..........................:  Not directly connected to the 
mains.  
N/A 
 
Rated voltage(s) or voltage range(s) (V)  ...............:  24V
 
 
Symbol for nature of supply, for d.c. only ...............:  IEC 60417-5031 used. 
See above. 
 
Rated frequency or rated frequency range (Hz)  ....:  DC source. 
N/A 
 
Rated current (mA or A)  ........................................:  2.3A 
1.7.1.2 
Identification markings 
See below.  
 
Manufacturer’s name or trade-mark or identification 
mark .......................................................................: 
 
 
Model identification or type reference ....................:  Go + Play micro 
 
Symbol for Class II equipment only  .......................:  Class III equipment. 
N/A 
 
Other markings and symbols .................................:  Other markings and symbols 
do not give rise to 
misunderstanding. 
1.7.2 
Safety instructions and marking 
Provided with marking 
regarding use of specified 
power supply, refer to copy of 
marking plate. 
1.7.2.1 
General 
Instructions are available. 
1.7.2.2 
Disconnect devices 
Not directly connected to the 
mains.  
N/A 
1.7.2.3 
Overcurrent protective device 
Not directly connected to the 
mains.  
N/A 
1.7.2.4 
IT power distribution systems 
Not directly connected to the 
mains.  
N/A 
1.7.2.5 
Operator access with a tool 
 
N/A 
1.2.7.6 
Ozone 
 
N/A 
1.7.3 
Short duty cycles 
Equipment is designed for 
continuous operation. 
N/A 
1.7.4 
Supply voltage adjustment ....................................: 
No supply voltage adjustment. 
N/A 