GO PLAY MICRO (serv.man2) - Harman Kardon Audio EMC - CB Certificate (repair manual). Page 15

Read Harman Kardon GO PLAY MICRO (serv.man2) EMC - CB Certificate online

 
Page 14 of 58 
Report No. 15039146 001 
 
 
 
IEC 60950-1 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
 
TRF No. IEC60950_1B 
 
 
2.9.3 
Grade of insulation 
Functional insulation. 
2.9.4 
Separation from hazardous voltages 
 
N/A 
 
Method(s) used ..................................................... : 
 
 
 
2.10 
Clearances, creepage distances and distances through insulation 
2.10.1 
General  
Only SELV inside the unit. 
2.10.1.1 
Frequency ..............................................................:   
N/A 
2.10.1.2 
Pollution degrees  ...................................................:  2 
2.10.1.3 
Reduced values for functional insualtion 
See 5.3.4. 
2.10.1.4 
Intervening unconnected conductive parts 
 
N/A 
2.10.1.5 
Insulation with varying dimensions 
 
N/A 
2.10.1.6 
Special separation requirements 
 
N/A 
2.10.1.7 
Insulation in circuits generating starting pulses 
 
N/A 
2.10.2 
Determination of working voltage 
 
N/A 
2.10.2.1 
General 
 
N/A 
2.10.2.2 
RMS working voltage 
 
N/A 
2.10.2.3 
Peak working voltage 
 
N/A 
2.10.3 
Clearances 
 
N/A 
2.10.3.1 
General 
 
N/A 
2.10.3.2 
Mains transient voltages 
 
N/A 
 
a) AC mains supply ................................................:   
N/A 
 
b) Earthed d.c. mains supplies  ..............................:   
N/A 
 
c) Unearthed d.c. mains supplies  ..........................:   
N/A 
 
d) Battery operation  ...............................................:   
N/A 
2.10.3.3 
Clearances in primary circuits 
(see appended table 2.10.3 
and 2.10.4)   
N/A 
2.10.3.4 
Clearances in secondary circuits 
(see appended table 2.10.3 
and 2.10.4)   
N/A 
2.10.3.5 
Clearances in circuits having starting pulses 
(see appended table 2.10.3 
and 2.10.4)   
N/A 
2.10.3.6 
Transients from a.c. mains supply .........................:   
N/A 
2.10.3.7 
Transients from d.c. mains supply .........................:   
N/A 
2.10.3.8 
Transients from telecommunication networks and 
cable distribution systems ......................................: 
 
N/A 
2.10.3.9 
Measurement of transient voltage levels 
 
N/A 
 
a) Transients from a mains suplply 
 
N/A 
 
For an a.c. mains supply ........................................:   
N/A 
Page of 70