Report No. 15039146 001 
 
 
 
IEC 60950-1 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
 
TRF No. IEC60950_1B 
 
 
 
- Basic insulation not under stress .........................:   
N/A 
 
- Supplemetary, reinforced insulation  ....................:   
N/A 
2.10.6 
Construction of printed boards 
 
N/A 
2.10.6.1 
Uncoated printed boards 
(see appended table 2.10.3 
and 2.10.4) 
N/A 
2.10.6.2 
Coated printed boards 
(see appended table 2.10.3 
and 2.10.4) 
N/A 
2.10.6.3 
Insulation between conductors on the same inner 
surface of a printed board 
(see appended table 2.10.3 
and 2.10.4) 
N/A 
2.10.6.4 
Insulation between conductors on different layers of 
a printed board 
 
N/A 
 
Distance through insulation 
(see appended table 2.10.5) 
N/A 
 
Number of insulation layers (pcs) ...........................:   
N/A 
2.10.7 
Component external terminations 
(see appended table 2.10.3 
and 2.10.4) 
N/A 
2.10.8 
Tests on coated printed boards and coated 
components 
 
N/A 
2.10.8.1 
Sample preparation and preliminary inspection 
 
N/A 
2.10.8.2 
Thermal conditioning 
 
N/A 
2.10.8.3 
Electric strength test 
(see appended table 5.2) 
N/A 
2.10.8.4 
Abrasion resistance test 
 
N/A 
2.10.9 
Thermal cycling 
 
N/A 
2.10.10 
Test for Pollution Degree 1 environment and 
insulating compound 
 
N/A 
2.10.11 
Tests for semiconductor devices and cemented 
joints 
 
N/A 
2.10.12 
Enclosed and sealed parts 
 
N/A 
 
 
 
 
WIRING, CONNECTIONS AND SUPPLY 
 
3.1 
General 
See below.  
3.1.1 
Current rating and overcurrent protection 
The cross-sectional area of the 
wires is adequate and 
complied with the tests of 4.5.2 
and 4.5.3. 
3.1.2 
Protection against mechanical damage 
The wireways (including 
holes) are smooth and free 
from sharp edges. 
3.1.3 
Securing of internal wiring 
No excessive strain on wire 
and on terminal connections, 
loosing of terminal 
connections and damage of 
conductor insulation. 
Page of 70
Display

Click on the first or last page to see other GO PLAY MICRO (serv.man2) service manuals if exist.