Read Harman Kardon DPR 1005 (serv.man11) EMC - CB Certificate online
-
IEC 60065, 6th edition : 1998
-
- Page 13 of 15 -
Order
No.
34625
FAULT CONDITION TESTS (Continued)
P
Comp.
No
No
Fault Test
V
Point Test
time
Fuse No
Current
through
fuse
through
fuse
Mains power/temperatures/results
Pmax.
opening
- 233,2
- 3
hr
30 min
F101
4,12 A
Normar operated.
Components are heated-up to (
Components are heated-up to (
∆
t);
- T101 coil
: 71K
- T101 core
: 49K
- T102 coil
: 44K
- T103 coil
: 71K
- T201 coil
: 51K
- T202 coil
: 49K
- LF101 coil
: 33K
- LF102 coil
: 32K
- Amp heat-sink : 31K
and stabilised.
Input current stabilised at 4,10 A.
Dielectric strength test O.K.
No hazard
and stabilised.
Input current stabilised at 4,10 A.
Dielectric strength test O.K.
No hazard
.
F No = Fault Number, S-c = Short-circuit, Dis = Disconnection