IEC 60065, 6th edition : 1998
 - 
- Page 13 of 15 - 
 
 
   
 Order 
No. 
34625
 
 
 
                     
 
 
 
 
 
FAULT CONDITION TESTS (Continued) 
P
Comp. 
No 
Fault Test 
Point Test 
time 
Fuse No
Current 
through 
fuse 
Mains power/temperatures/results 
Pmax. 
opening 
- 233,2 
- 3 
hr 
30 min 
F101
 
4,12 A 
Normar operated. 
Components are heated-up to (
t);
- T101 coil 
: 71K 
- T101 core 
: 49K 
- T102 coil 
: 44K 
- T103 coil   
: 71K 
- T201 coil 
: 51K 
- T202 coil 
: 49K 
- LF101 coil 
: 33K 
- LF102 coil 
: 32K 
- Amp heat-sink    : 31K   
and stabilised.   
Input current stabilised at 4,10 A. 
Dielectric strength test O.K. 
No hazard
 
 
 
 
 
 
 
 