DPR 1005 (serv.man11) - Harman Kardon Audio EMC - CB Certificate (repair manual). Page 8

Read Harman Kardon DPR 1005 (serv.man11) EMC - CB Certificate online

 - 
IEC 60065, 6th edition : 1998
 - 
- Page 6 of 15 - 
 
 
   
 Order 
No. 
34625
 
 
 
                     
 
 
 
 
7.1 
Operating conditions:   
Sine wave 1000Hz input, set to 1/8 of maximum output power for Front, 
Center, Surr. and Surr.Back channels.
 
 U 
= 
198,0
 V
, I 
= 
1,07
 A
, P 
= 
132 
W
, 
Pout = 
2 x 9,05 
(F)
 
   
 
 
 
 
 
 
1 x 9,23
 W 
(C)
 
   
 
 
 
 
 
 
2 x 8,86 
(S) 
   
 
 
 
 
 
 
2 x 9,16
 W 
(S/B)
 
 U 
= 
233,2
 V
, I 
= 
0,98
 A
, P 
= 
136 
W
, 
Pout = 
2 x 9,05 
(F)
 
   
 
 
 
 
 
 
1 x 9,23
 W 
(C)
 
   
 
 
 
 
 
 
2 x 8,86 
(S) 
   
 
 
 
 
 
 
2 x 9,16
 W 
(S/B)
 
 LSL 
 
=            
        x 7 channels ( Front: 2, Center: 1, Surround: 2, Surround Back: 2 )
 
 
 
 
Loudspeaker system(s) 
 
Right and Left for Front, 
   
 
One for Center, 
   
 
Right and Left for Surround Back, 
   
 
Right and Left for Surround channels.
 
 
Marking of loudspeaker terminals 
SPEAKERS 8
 
 
   
 
CENTER, FRONT L / R, 
   
 
SURR. L / R, SBL / MULTI L / R.
 
 
 
U =
 233,2 
V
 
4 Ohm 
8 Ohm 
16 Ohm 
 
 6 
Ohm 
 
Left  Right 
Left 
Right 
Left Right 
Left Right
Measured output voltage    in Vp 
 
 
F) 34,0 
C) 34,4 
S) 33,7 
S/B) 34,2 
F) 34,0 
C) - 
S) 33,7 
S/B) 34,2 
 
 
 
 
Measured output power    in W
 
 
 
 
F) 72,4 
C) 73,8 
S) 70,9 
S/B) 73,3 
F) 72,4 
C) - 
S) 70,9 
S/B) 73,3 
 
 
 
 
Measured mains power    in W
 
 
 
671 
 
 
Page of 17