Read Harman Kardon DPR 1005 (serv.man11) EMC - CB Certificate online
-
IEC 60065, 6th edition : 1998
-
- Page 7 of 15 -
Order
No.
34625
HEATING
∆
t = ( R2 - R1) x (234,5 + t1) - (t2 - t1)
R1
P
t1 =
24,4 °C
24,4 °C
t2 =
24,1 °C
22,9 °C
Test voltage
198 V
233,2 V
Winding
R1/
Ω
R2/
Ω
∆
t measured
∆
t allowed
Insulation
class
class
T101 winding at 198 V
575
688
51,2
85
Class E
T101 winding at 233,2 V
575
711
62,7
85
Class E
Other measured parts
∆
t measured
at 198V,60Hz
∆
t measured
at 233V,60Hz
∆
t allowed
Linear transformer, T101 core
31,2
37,2
85
Switching transformer, T102 core
22,1
24,1
70
Switching transformer, T102 coil
25,2
27,1
70
Switching transformer, T103 core
24,7
26,1
70
Switching transformer, T103 coil
25,6
27,9
70
Switching transformer, T201 core
23,5
25,5
70
Switching transformer, T201 coil
24,6
26,9
70
Switching transformer, T202 core
23,4
25,5
70
Switching transformer, T202 coil
25,1
27,9
70
Line chock, T203 coil
25,3
27,1
70
Reactor, PT01 coil
15,4
15,6
70
Line filter, LF101 coil
13,5
14,9
70
Line filter, LF102 coil
12,2
13,5
70
PFC, L206 coil
19,4
21,3
70
Diode, BD101 body
22,4
24,0
-
PWB near BD101
21,5
23,2
85
PWB near D215
29,2
32,1
85
HS102
heat-sink
24,9 28,2 -
E. Capacitor, C107 body
20,6
22,1
85°C
PWB near Q105
24,1
27,3
85
PWB near U101
24,8
27,0
85
Click on the first or last page to see other DPR 1005 (serv.man11) service manuals if exist.