IEC 60065, 6th edition : 1998
-
- Page 8 of 15 -
Order
No.
34625
Other measured parts (continued)
∆
t measured
at 198V,60Hz
∆
t measured
at 233V,60Hz
∆
t allowed
HS104
heat-sink
1,9 2,4 -
Heat-sink in Amp. module
23,4
24,6
-
Top enclosure above Amp. Module
10,2
11,7
40
Top enclosure above SMPS
13,5
15,2
40
Appliance inlet body
11,4
11,7
60
Switch button (standby / on)
0,6
1,8
50
Comments
No other parts were observed to create any hazard due to temperature rise.
P
9
ELECTRIC SHOCK HAZARD
UNDER NORMAL OPERATING
CONDITIONS
UNDER NORMAL OPERATING
CONDITIONS
P
9.1.1
Touch current expressed as
voltages U1 and U2 in Annex D
voltages U1 and U2 in Annex D
P
Location Measured
U1
V (peak)
Measured U1
V (DC)
V (DC)
Measured U2
V (peak)
V (peak)
Limits :
U1 Max 35V (peak)
U1 Max 1.0V (DC)
U2 Max 0.35V
(peak)
U1 Max 35V (peak)
U1 Max 1.0V (DC)
U2 Max 0.35V
(peak)
Mains pole 1 – Video Out Terminal
0,44 V (peak)
-
0,31 V (peak)
Pass
Mains pole 2 – Video Out Terminal
0,47 V (peak)
-
0,30 V (peak)
Pass
Discharge not exceeding 45
µ
C
No part or contact of a terminal with stored voltages
between 60V - 15kV
between 60V - 15kV
N
Energy of discharge not exceeding
350 mJ
350 mJ
No part or contact of a terminal with stored voltages
exceeding 15kV
exceeding 15kV
N
Test with test finger according to test
probe B of IEC 61 032 (20N)
probe B of IEC 61 032 (20N)
No access to hazardous live parts
P
For class II constructions, test with
test probe 13 of IEC 61 032 (3N)
test probe 13 of IEC 61 032 (3N)
No access to hazardous live parts
P
Clearances to circuits exceeding
1000V a.c. or 1500V d.c.
1000V a.c. or 1500V d.c.
No voltages exceeding 1000V AC or 1500V DC.
N