Read Harman Kardon DPR 1005 (serv.man11) EMC - CB Certificate online
-
IEC 60065, 6th edition : 1998
-
- Page 11 of 15 -
Order
No.
34625
FAULT CONDITION TESTS
P
Ambient temperature
23 -25 °C
Rated voltage
220V~
Remarks
-
Comp.
No
No
Fault Test
V
Point Test
time
Fuse No
Current
through
fuse
through
fuse
Mains power/temperatures/results
BD101
S-c
233,2
AC - (+)
1 sec.
F101
-
F101 opened immediately.
No hazard.
No hazard.
BD101
S-c
198
AC - (+)
1 sec.
F101
-
F101 opened immediately.
No hazard.
No hazard.
C106
S-c
233,2
-
1 sec.
F101
6,10 A
F101 opened after 3 sec.
No hazard.
No hazard.
C106 S-c 198 -
1
min.
25 sec.
F101
1,60 A
C107 venred after 1 min. 25 sec.
and F101 opened.
Dielectric strength test OK.
No hazard.
and F101 opened.
Dielectric strength test OK.
No hazard.
C108 S-c 233,2 -
1
hr.
40 min
F101
1,20 A
Normal operated.
Input current stabilised at 0,90A.
R123 opened. No hazard.
Input current stabilised at 0,90A.
R123 opened. No hazard.
BD201
S-c
233,2
AC – (+) 16 min
F101
0,18 A
Unit shut down immediately.
T101 primary winding heated up to
129K and thermal fuse opened
after 16 min.
Input current stabilised at 0,17 A.
Dielectric strength test OK.
No hazard.
T101 primary winding heated up to
129K and thermal fuse opened
after 16 min.
Input current stabilised at 0,17 A.
Dielectric strength test OK.
No hazard.
D206
S-c
233,2
A - C
30 min
F101
1,00 A
Unit shut down after 3 min.
Input current stabilised at 0,16 A.
T102 winding heated up to 82K.
D206, T102 damaged.
Dielectric strength test OK.
No hazard.
Input current stabilised at 0,16 A.
T102 winding heated up to 82K.
D206, T102 damaged.
Dielectric strength test OK.
No hazard.
D207
S-c
233,2
A - C
10 min
F101
1,12 A
Unit shut down after 4 min.
Input current stabilised at 0,16 A.
T102 winding heated up to 94K.
D207, T102 damaged.
Dielectric strength test OK.
No hazard.
Input current stabilised at 0,16 A.
T102 winding heated up to 94K.
D207, T102 damaged.
Dielectric strength test OK.
No hazard.
D217
S-c
233,2
A - C
1 hr.
40 min
40 min
F101
1,70 A
Unit shut down immediately.
Input current stabilised at 0,16 A.
No component damaged.
No hazard.
Input current stabilised at 0,16 A.
No component damaged.
No hazard.
F No = Fault Number, S-c = Short-circuit, Dis = Disconnection
Click on the first or last page to see other DPR 1005 (serv.man11) service manuals if exist.