Read Harman Kardon DPR 1005 (serv.man11) EMC - CB Certificate online
-
IEC 60065, 6th edition : 1998
-
- Page 9 of 15 -
Order
No.
34625
9.1.2
No hazardous live shafts of knobs,
handlers or levers
handlers or levers
No live shafts, handles or levers
N
9.1.3
Ventilation holes tested by means of
4 mm x 100 mm test pin
4 mm x 100 mm test pin
No access for the test pin.
P
9.1.4
Terminal devices tested with
1 mm x 20 mm test pin (10 N); test
probe 16 of IEC 61 032
1 mm x 20 mm test pin (10 N); test
probe 16 of IEC 61 032
Does not reach hazardous live parts
P
Terminal devices tested with
1 mm x 100 mm straight wire (1 N);
test probe D of IEC 61 032
1 mm x 100 mm straight wire (1 N);
test probe D of IEC 61 032
Does not reach hazardous live parts
P
9.1.5
Pre-set controls tested with
2.5 mm x 100 mm test pin (10 N);
test probe C of IEC 61 032
2.5 mm x 100 mm test pin (10 N);
test probe C of IEC 61 032
No preset controls
N
9.1.6
No shock hazard due to stored
charge on withdrawal of the mains
plug; voltage (V) after 2 s
charge on withdrawal of the mains
plug; voltage (V) after 2 s
0V after 2 sec.
Discharge resistor provided, R102, 1M
Discharge resistor provided, R102, 1M
Ω
, 1/2W.
P
If C is not greater than 0,1
µ
F no test
needed
N
10 INSULATION
REQUIREMENTS
P
10.1
Insulation resistance (M
Ω
) at least
2 M
Ω
min. after surge test for basic
and 4 M
Ω
min. for reinforced
insulation
> 4 M
Ω
P
10.2
Humidity treatment 48 h or 120 h
48 h (30
°
C). No impairment
P
10.3
Insulation resistance and dielectric
strength
strength
P
Tested insulation
Insulation
Test voltage
Voltage test
Remarks
Resistance
based on the
(r.m.s.value)
(M Ohm)
Operating
Meas-
Min.
Voltage
Ured
required
(V)
(V)
Between the poles
For rated mains
of the circuit
:
> 2
2
voltages
≤
150V
directly connected
r.m.s, 1410V pk
to the supply
mains
For rated mains
voltages
≥
150V
1500 V
Pass
r.m.s, 2120V pk
Basic insulation
:
> 100
2
Curve A,
1500 V
Pass – (reactor insulation)
Fig.
7
Supplementary
insulation
:
2
Curve A,
Fig.
7
Reinforced
insulation
:
> 4
4
Curve B,
3000 V
Pass
Fig.
7
Click on the first or last page to see other DPR 1005 (serv.man11) service manuals if exist.