DPR 1005 (serv.man11) - Harman Kardon Audio EMC - CB Certificate (repair manual). Page 11

Read Harman Kardon DPR 1005 (serv.man11) EMC - CB Certificate online

 - 
IEC 60065, 6th edition : 1998
 - 
- Page 9 of 15 - 
 
 
   
 Order 
No. 
34625
 
 
 
                     
 
 
 
 
9.1.2 
No hazardous live shafts of knobs, 
handlers or levers   
No live shafts, handles or levers 
9.1.3 
Ventilation holes tested by means of 
4 mm x 100 mm test pin   
No access for the test pin. 
 
9.1.4 
Terminal devices tested with 
1 mm x 20 mm test pin (10 N); test 
probe 16 of IEC 61 032   
Does not reach hazardous live parts 
 
Terminal devices tested with 
1 mm x 100 mm straight wire (1 N); 
test probe D of IEC 61 032   
Does not reach hazardous live parts 
9.1.5 
Pre-set controls tested with 
2.5 mm x 100 mm test pin (10 N); 
test probe C of IEC 61 032   
No preset controls 
9.1.6 
No shock hazard due to stored 
charge on withdrawal of the mains 
plug; voltage (V) after 2 s      
0V after 2 sec. 
Discharge resistor provided, R102, 1M
, 1/2W. 
 
If C is not greater than 0,1 
µ
F no test 
needed  
 
 
10 INSULATION 
REQUIREMENTS 
 
 
10.1 
Insulation resistance (M
) at least 
2 M
 min. after surge test for basic 
and 4 M
 min. for reinforced 
insulation    
> 4 M
 
10.2 
Humidity treatment 48 h or 120 h      
48 h (30
°
C). No impairment 
10.3 
Insulation resistance and dielectric 
strength   
 
Tested insulation 
Insulation   
Test voltage 
Voltage test 
Remarks 
 
Resistance 
based on the 
(r.m.s.value) 
 
 
     (M Ohm) 
Operating 
 
 
 Meas- 
Min. 
Voltage 
 
 
 Ured 
required 
(V) 
(V) 
 
Between the poles 
 
 
For rated mains 
 
 
of the circuit    
:
 
> 2 
 2 
voltages 
 150V
 
 
directly connected 
 
 
r.m.s, 1410V pk 
 
 
to the supply 
 
 
 
 
 
mains 
 
 
For rated mains 
 
 
 
 
 
voltages 
 150V
1500 V 
Pass 
 
 
 
r.m.s, 2120V pk 
 
 
Basic insulation 
:
 
> 100 
 2 
Curve A,
 
 
1500 V 
Pass – (reactor insulation) 
  
 
Fig. 
 
 
Supplementary  
  
 
 
insulation   
 
:
 
 
 2 
Curve A,
 
 
 
   
  
 
Fig. 
 
 
Reinforced  
 
 
 
 
insulation               
:
 
> 4 
 4 
Curve B,
 
 
3000 V 
Pass 
  
 
Fig. 
 
 
 
Page of 17
Display

Click on the first or last page to see other DPR 1005 (serv.man11) service manuals if exist.